S
ECTION
3 MAIN SOFTWARE UPGRADING
3.1 General
The main system software is initially stored in the Flash memory located on the CPU card of the Main
KSU. It can be upgraded by the new software on the CF (Compact Flash) card.
3.2 Before Upgrading the Main Software
NEC recommends that a backup of the customer data is performed before
upgrading the main software (either PCPro file or CF card backup).
Before upgrading the main system software, the following preparations are necessary.
• Prepare the CF Card (32MB, or upwards and formatting by FAT(16)), and store the new main
software on the CF card by PC. (New main system software is supplied by NEC.)
• Install the PZ-VM21 PCB. (if the system does not have it.)
3.3 Main Software Version Confirmation
The Main software version is confirmed by the following operation at the display type Multiline
Telephone.
1.
On-hook Condition.
TUE18 7:27PM
200
Figure 4-14 Display of Multiline Telephone
2.
Press Enter Key (Navigation Key).
100:OPRN LST 1/4
>Call History:00
3.
Dial
821
to show the Main Software version & Hardware Key Code.
Main Ver: 01.00
HWK:XXXXXXXXXXXX
4.
Press Right Key (Navigation Key) to show the Main Software version & MAC address.
Main Ver: 01.00
0060-XXXX-XXXX
5.
Off-Hook and return to Time & Date mode.
TUE18 7:27PM
200
ISSUE 3.0
SL1000
Hardware Manual
4-9
Содержание SL1000
Страница 1: ...Hardware Manual A50 031170 001 GE ISSUE 3 0 November 2012...
Страница 12: ...MEMO SL1000 ISSUE 3 0 x Hardware Manual...
Страница 16: ...MEMO SL1000 ISSUE 3 0 R 4 Regulatory...
Страница 126: ...MEMO SL1000 ISSUE 3 0 3 8 System Start Up...
Страница 140: ...MEMO SL1000 ISSUE 3 0 4 14 Maintenance...
Страница 149: ...MEMO ISSUE 3 0 SL1000 Hardware Manual 5 9...
Страница 150: ...Hardware Manual NEC Corporation ISSUE 3 0...