2-30 System Configuration
Current readings are displayed for temperature, power supply voltages,
and chassis state.
Interrupts can be detected when “out of range” conditions occur. User
prompts are displayed to alert the user to a potentially harmful condition.
Using the Chassis Intrusion Notification Feature
LANDesk Client Manager allows the user to monitor the system against chassis
intrusion. Whenever the chassis is opened, LANDesk Client Manager logs the
intrusion and reports the incident in a screen message the next time the system is
booted. The message appears in a LANDesk Client Manager Notification
window. The window appears every time the system is rebooted until the report
is cleared.
Close the notification window to remove the message from the screen. Clear the
message to prevent it from appearing again the next time the system is rebooted.
To clear the message, follow these steps.
1.
Access LANDesk Client Manager.
If the LANDesk Client Manager Notification window is still open, click
Yes
, and then click the
Client Manager
button.
From the Windows desktop, click
Start
on the taskbar, point to
Programs, point to
LANDesk Client Manager
, and click
LANDesk
Client Manager 3.1
.
LANDesk Client Manager opens.
2.
Open the Tools menu and click
PC Health
. The PC Health window appears.
The Chassis Opened field displays the
Yes
setting.
3.
Click
Clear
next to the Chassis Opened field.
4.
Exit from LANDesk Client Manager.
NEC Auto Backup
On systems that use the Windows 95 operating system, NEC Auto Backup is a
data management and backup program that operates in conjunction with
LANDesk Client Manager’s DMI and the Self-Monitoring Analysis and
Reporting Technology (S.M.A.R.T.) Hard Drive instrumentation. If the
S.M.A.R.T. drive identifies a potential problem, the NEC Auto Backup utility
automatically invokes the Cheyenne Backup program and backs up the entire
file system to a user-selected backup device, such as a tape drive, Zip drive, or
network drive.
Содержание POWERMATE 5100 - SERVICE
Страница 15: ...1 System Overview Configurations Features Components ...
Страница 28: ...2 System Configuration Interrupt Requests Jumper Settings BIOS Setup Video Modes Utilities ...
Страница 108: ...4 System Board Connectors Jumpers and Sockets Components Pin Assignments Resources ...
Страница 162: ...6 Illustrated Parts Breakdown Parts and Options Field Replaceable Unit FRU List Illustrated Parts Breakdown IPB ...
Страница 167: ...7 Preventive Maintenance System Cleaning Keyboard Cleaning Mouse Cleaning ...
Страница 171: ...8 Troubleshooting Checklist Diagnostics ...
Страница 181: ...9 NEC CSD Information Services Service Telephone Numbers Technical Support Product Information FaxFlash Service ...
Страница 205: ...A Release Notes General Notes Windows 95 Issues Windows NT Issues ...