CHAPTER 11 SERIAL INTERFACE 20
190
User’s Manual U15331EJ4V1UD
11.3 Serial Interface 20 Control Registers
Serial interface 20 is controlled by the following six registers.
•
Serial operation mode register 20 (CSIM20)
•
Asynchronous serial interface mode register 20 (ASIM20)
•
Asynchronous serial interface status register 20 (ASIS20)
•
Baud rate generator control register 20 (BRGC20)
•
Port mode register 2 (PM2)
•
Port 2
(1) Serial operation mode register 20 (CSIM20)
CSIM20 is used to make the settings related to 3-wire serial I/O mode.
CSIM20 is set with a 1-bit or 8-bit memory manipulation instruction.
RESET input sets CSIM20 to 00H.
Figure 11-3. Format of Serial Operation Mode Register 20
CSIE20
0
1
3-wire serial I/O mode operation control
CSIE20
0
0
0
0
DIR20 CSCK20
0
CSIM20
Symbol
Address
After reset
R/W
FF72H
00H
R/W
<7>
6
5
4
3
2
1
0
Operation disabled
Operation enabled
DIR20
0
1
First-bit specification
MSB
LSB
CSCK20
0
1
3-wire serial I/O mode clock selection
External clock input to the SCK20 pin
Output of the dedicated baud rate generator
Cautions 1. Bits 0 and 3 to 6 must be set to 0.
2. CSIM20 must be cleared to 00H if UART mode is selected.
3. When the external input clock is selected in 3-wire serial I/O mode, set input mode by
setting bit 0 of port mode register 2 (PM2) to 1.
4. Switch operating modes after halting the serial transmit/receive operation.