CHAPTER 7 8-BIT TIMERS 50, 60, AND 61
User’s Manual U15331EJ4V1UD
159
Figure 7-29. PPG Output Mode Timing (Basic Operation)
Count clock
TM6m
count value
CR6m
TCE6m
INTTM6m
00H
N
00H
01H
N
CRH6m
M
N
TO6m
Note
00H
00H
01H
M
01H
01H
M
00H
Clear
Clear
Clear
Clear
Count start
Note
The initial value of TO6m is low level when output is enabled (TOE6m0 = 1).
Remark
N, M = 00H to FFH
m = 0, 1
Figure 7-30. PPG Output Mode Timing (When CR6m and CRH6m Are Overwritten)
Count clock
TM6m
count value
CR6m
TCE6m
INTTM6m
00H
N
00H
01H
N
CRH6m
M
N
TO6m
Note
M
X
Y
00H
00H
X
00H
X
Y
M
Clear
Clear
Clear
Clear
Count start
Note
The initial value of TO6m is low level when output is enabled (TOE6m0 = 1).
Remark
N, M, X, Y = 00H to FFH
m = 0, 1