CHAPTER 7 8-BIT TIMERS 50, 60, AND 61
User’s Manual U15331EJ4V1UD
132
(4) 8-bit timer mode control register 61 (TMC61)
8-bit timer mode control register 61 (TMC61) is used to control the timer 61 count clock setting and the
operation mode setting.
TMC61 is set with a 1-bit or 8-bit memory manipulation instruction.
RESET input sets this register to 00H.
Figure 7-9. Format of 8-Bit Timer Mode Control Register 61
Symbol
<7>
6 5 4 3 2 1
<0>
Address
After
reset
R/W
TMC61 TCE61
0
TCL612 TCL611 TCL610 TMD611 TMD610 TOE610
FF41H
00H
R/W
TCE61
Control of TM61 count operation
0
Clear TM61 count value and stop operation
1
Start count operation
TCL612
TCL611
TCL610
Selection of timer 61 count clock
Note
0 0 0
f
X
(5.0 MHz)
0 0 1
f
X
/2
4
(313 kHz)
0 1 0
f
TMI
0 1 1
f
TMI
/2
1 0 0
f
TMI
/2
2
1 0 1
f
TMI
/2
3
Other than above
Setting prohibited
TMD611
TMD610
Selection of operation mode for timer 61
Note
0
0
Stand-alone mode (8-bit counter mode)
1
0
PPG output mode
Other than above
Setting prohibited
TOE610
Control of timer output
0
Output
disabled
1
Output
enabled
Note
To set the register in 24-bit event counter mode, the external input clock and stand-alone mode need to
be selected.
Caution To manipulate TMC61, follow the setting procedure below.
<1> Set the TM61 count operation to stop.
<2> Set the operation mode and count clock.
<3> The count operation starts.
Remarks 1.
f
X
: Main system clock oscillation frequency
2.
f
TMI
: External input clock frequency
3.
The parenthesized values apply to operation at f
X
= 5.0 MHz.
Содержание PD789488