Base Module
855-900547-200 2-78
2.4.6.11. RS (Cold Reset System)
m b u
X
* The command is executable to the active partition (after automatic system boot/UP
command execution).
Function:
This command causes the system to be cold-reset.
Note that this command could reset the system while the OS (BIOS) is running, notifying
nothing to the software.
Partitions that are already off or those being shut down are not the target of this command.
(Screen Example)
Description
No.
iSPyz:--->
rs
<ENTER>
CAUTION: System will be resetted without any notice to the softwares even if
they are running.
Enter partition number (0-7/all/CR=exit) :
0
<ENTER>
(a)
Execute OK? (y/[n])
y
<ENTER>
(b)
RS command was accepted. All partitions will be reset soon.
(c)
mm/dd/yyyy HH:MM:SS 0------- System shutdown started. (SPFW:Rxx.xx)
:
mm/dd/yyyy HH:MM:SS 0------- System shutdown completed. (SPFW:Rxx.xx)
mm/dd/yyyy HH:MM:SS 0------- System initialization started. (SPFW:Rxx.xx)
:
mm/dd/yyyy HH:MM:SS 0------- System initialization completed. (SPFW:Rxx.xx)
[iSP0m:INFO.2129] partition 0 : handed off the control to BIOS.
(DIPSW = 00000000)
(d)
(Description)
Description
No.
Description
(a)
Prompts a partition number.
If “all” is specified, all the existing partitions are the target of this command.
(b)
Enter y at this confirmation message if you are sure to continue command
execution.
(c)
An “RS command accepted” message appears.
The actual processing progresses in the background.
(d)
Shows the progress in the background.
Содержание NX7700i/5080H-32
Страница 19: ...xviii 420 422...
Страница 26: ...xxv 5 2 DVD ROM CD ROM 5 1 5 3 Digital Audio Tape 5 1 5 4 Cleaning 5 2 5 5 Notes on Installation 5 3...
Страница 41: ...Base Module 855 900547 200 2 5 Figure 2 5 PCIBAY Numbers in the Main Cabinet PCIBAY0 PCIBAY2 PCIBAY3 PCIBAY1...
Страница 50: ...Base Module 855 900547 200 2 14 Figure 2 13 Loading and Unloading DAT DAT slot Main Cabinet I O MODULE...
Страница 170: ...Notes on Handling 855 900547 200 5 4 Memo...