![NEC NX7700i/5080H-32 Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/nec/nx7700i-5080h-32/nx7700i-5080h-32_operation-manual_4280842096.webp)
Base Module
855-900547-200 2-60
Description of Status Indicator Strings
Indicator
string
Description
nonexist.
Indicates that a resource is defined to be non-existent (the iSP does not
assume that it “should” be existent).
INVISIBLE
The iSP assumes that the resource “should” be existent, but actually the
resource is not visible to the iSP due to a failure or removal of a card.
Once a resource is visible to the iSP (whether it is automatically detected or
manually configured), it is subsequently assumed to be “existent” unless it is
explicitly deleted with the delete command.
power-off
Indicates that the DC power is Off.
On some components, the DC power is activated immediately when the AC
power is applied.
power-ON
Indicates that the DC power is On.
On some components, this indicator may be overwritten with any of the
following indicators.
offline
Indicates that the component’s DC power is On but it is not connected to the
system as viewed from the software (OS or BIOS).
ONLINE
Indicates that the component’s DC power is On and it is connected to the
system as viewed from the software (OS or BIOS).
MASTER
This indicator is only valid for iSP/CLK status display. It indicates that the
component is assigned as the master.
When the CLK is assigned as the master, it means that it supplies the CELL
and XBX Cards with the clocks.
backup
This indicator is only valid for iSP/CLK status display. It indicates that the
component is assigned as backup.
The CLK, if assigned as backup, is supplying the CELL or XBX Cards with no
clocks. The backup indicator is active when the system is in Halt mode.
enable
Indicates that the component itself is valid (used for system operation).
enable-
Indicates that the component itself is valid but is reserved by software, etc. so
it will not be used for system operation on a next boot.
enable*
Indicates that the component is invalid on a next shut-down due to
component’s own failure.
DISABLE
Indicates that the component itself is invalid (not used for system operation).
The component is manually disconnected with the disable command.
DISABLE*
Indicates that the component itself is invalid (not used for system operation).
The component is disconnected due to component’s own failure.
It should not be connected to the system until the failure is serviced.
DISABLE&
Indicates that the component itself is made invalid by a software request, and
is to stay invalid on a next boot.
Indicates that the component itself is made invalid by a software request, and
is reversed to become valid on a next boot.
DISABLE
.
Indicates that the component is invalid because it cannot be made valid due to
its upper-level components or system configuration restrictions, but is reserved
to be made valid on a next boot.
not used
Indicates an unused subcomponent.
DEG
Indicates that there are one or more subcomponents that are in DISABLE or
DISABLE. state.
RUN
Indicates that the partition (BIOS) is already booted.
INIT
Indicates that the partition is being booted.
FAIL
Indicates that the partition is in a fatal fault.
SHUT
Indicates that the partition is being shut down.
DIAG
Indicates that the partition is running an auxiliary CELL diagnosis.
P-ON
Indicates that the partition is powered On for expanded diagnosis.
stop
Indicates that the partition is inactive (DC power off).
Содержание NX7700i/5080H-32
Страница 19: ...xviii 420 422...
Страница 26: ...xxv 5 2 DVD ROM CD ROM 5 1 5 3 Digital Audio Tape 5 1 5 4 Cleaning 5 2 5 5 Notes on Installation 5 3...
Страница 41: ...Base Module 855 900547 200 2 5 Figure 2 5 PCIBAY Numbers in the Main Cabinet PCIBAY0 PCIBAY2 PCIBAY3 PCIBAY1...
Страница 50: ...Base Module 855 900547 200 2 14 Figure 2 13 Loading and Unloading DAT DAT slot Main Cabinet I O MODULE...
Страница 170: ...Notes on Handling 855 900547 200 5 4 Memo...