![NEC NX7700i/5080H-32 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/nec/nx7700i-5080h-32/nx7700i-5080h-32_operation-manual_4280842068.webp)
Base Module
855-900547-200 2-32
2.4.5.4.
SP Command List
The following tables contain SP command lists by category:
System Control
CMD command
name
function
iSP
state
DF
Shut down System power
(override)
The iSP turns off the DC power of the
specified partition without notifying the
SW (OS) even if it is running.
m
DN
Shut down System power
If the specified partition is in S0 state,
the iSP only generates the SCI
(POWBTN). Otherwise, the iSP turns
off the DC power directly.
m
DP System
Dump
The iSP generates the INIT signal to
the specified partition. SW (OS) will
enter its dump routine.
m
PC Power
Cycle
The iSP turns off the DC power of the
specified partition without notifying the
SW (OS) even if it is running, turns on
the DC power, initializes HW and
hands off the control to the BIOS.
m
RS
Cold Reset System
The iSP initializes the specified
partition without notifying the SW (OS)
even if it is running.
m
UB
Bring up BIOS
The iSP turns on the DC power of the
specified partition and initializes HW
and hands off the control to the BIOS.
m
UP
Bring up System
The iSP turns on the DC power of the
specified partition and initializes HW
and hands off the control to the BIOS.
The BIOS will boot the Operating
System.
m
“m”: Commands can be executed only on the master iSP.
Содержание NX7700i/5080H-32
Страница 19: ...xviii 420 422...
Страница 26: ...xxv 5 2 DVD ROM CD ROM 5 1 5 3 Digital Audio Tape 5 1 5 4 Cleaning 5 2 5 5 Notes on Installation 5 3...
Страница 41: ...Base Module 855 900547 200 2 5 Figure 2 5 PCIBAY Numbers in the Main Cabinet PCIBAY0 PCIBAY2 PCIBAY3 PCIBAY1...
Страница 50: ...Base Module 855 900547 200 2 14 Figure 2 13 Loading and Unloading DAT DAT slot Main Cabinet I O MODULE...
Страница 170: ...Notes on Handling 855 900547 200 5 4 Memo...