4-8
TROUBLESHOOTING
“Confidential, Do Not Duplicate without written authorization from NEC.”
[1] Detect rule:
Error Code Message – Troubleshooting and what parts need to replace
ErrMsgOverTempInlet
When Inlet temp > 45 in stand by mode or
Force ECO mode toggle and Inlet temp > 43 continue 5 mins
Temp. is over spec. Check if there is anything blocks in inlet or replace Inlet thermal sensor.
ErrMsgOverTempDMD
When DMD temp > 70 in stand by mode or
Force ECO mode toggle and DMD temp > 70 continue 5 mins
Temp. is over spec. Check or replace DMD thermal sensor.
ErrMsgOverTempLamp
Thermal Break toggle and Polling time is 500ms.
Check or replace Lamp thermal break.
ErrMsgOverTempBallast1
When Blaster temp > 90 in stand by mode or
Force ECO mode toggle and Blaster temp > 90 continue 5 mins
Check or replace Ballast1 thermal break.
Byte 6
Definition
Byte 7
Definition
Bit 0
ErrMsgFan9DriverError
Bit 0
ErrMsgNotchFilterOpen [5]
Bit 1
ErrMsgFan10DriverError
Bit 1
Reserved
Bit 2
ErrMsgFan11DriverError
Bit 2
Reserved
Bit 3
ErrMsgFan12DriverError
Bit 3
Reserved
Bit 4
ErrMsgFan13DriverError
Bit 4
Reserved
Bit 5
ErrMsgFan14DriverError
Bit 5
Reserved
Bit 6
ErrMsgFan15DriverError
Bit 6
Reserved
Bit 7
ErrMsgFan16DriverError
Bit 7
Reserved