Contents 

Product Description, Lens Specs, Notes and Formulas 

Page 1 

Projection Distances and Screen Sizes 

Desktop 

Setup 

    Page 2 

Ceiling 

Installation    Page 3 

Lens Shift Adjustable Range 
 

TL-1ZH, TL-2Z and TL-4Z Lens 

 

 

Page 4 

TL-08SF 

Lens 

    Page 5 

Cabinet Dimensions 

Front, Bottom & Left Side   

 

 

Page 6 

Back, Top & Right Side 

 

 

 

Page 7 

Lens 

Dimensions 

     Page 8 

RS232 Control 
 Command 

Codes 

    Page 9 

 Connection 

    Page 10 

 

Product Description  

 

 

 

 

 

 

 

 

 

 

 

Type: 

  3 

chip, 

0.9" 

DLP 

  Dimensions: 

27.91"(W) x 16.85"(H) x 45.45"(D) w/handles, 

Native Resolution: 

1280 x 1024  (5:4) 

 

 

 

w/o lens 

Brightness: 

 

8000 ANSI Lumens 

 

Weight:   

185.3 lbs w/o lens 

Power Lens Shift/Power Zoom/Power Focus   

 

 

 

Lens Specification 

 

 

 

 

 

 

 

 

 

 

 

 

TL-08SF

      Throw Ratio:  0.84:1   

     F/#:   

        3.0  

 

Distortion (full offset): 

1% max 

 

     Screen Sizes:  80” - 500" (5:4)       Lateral color error:   14 

µ

max 

      

TL-1ZH

       Throw Ratio:  1.5 - 2.5:1 

     F/#:   

        3.0  

 

Distortion (full offset): 

2% max 

 

     Screen Sizes:  80" - 500" (5:4)       Lateral color error:   14 

µ

max 

      

TL-2Z

       Throw Ratio:  2.5 - 4.0:1 

     F/#:   

        3.0  

 

Distortion (full offset): 

2% max 

 

     Screen Sizes:  80" - 500" (5:4)       Lateral color error:   14 

µ

max 

      

TL-4Z

       Throw Ratio:  4.0 - 7.0:1 

     F/#:   

        3.0  

 

Distortion (full offset): 

2% max 

 

     Screen Sizes:  80” - 500" (5:4)       Lateral color error:   14 

µ

max 

      

 

Notes   

 

 

 

 

 

 

 

 

 

 

 

 

 

• 

For screen not indicated in the tables, use formulas below. 

• 

If the figures in the tables do not match the results of formulas, use the figures in the tables. 

• 

The ceiling must be strong enough to support the projector and the installation must be in accordance with any local building 
codes. 

• 

Distances are in inches, for millimeters multiply by 25.4 

• 

Distances may vary 

± 

5%. 

 

Formulas 

 

 

 

 

 

 

 

 

 

 

 

 

 

Throw Distance = Screen Width (H) x Lens Magnification  

 

H = Screen Width (5:4) 

H = Screen Height (V) x 5/4 

V = Screen Height (5:4) 

V = Screen Width (H) x 4/5 

 

 

 

 

 

Screen Diagonal (5:4) = Screen Height (V) x 6.4/4 

 

Note: 

Image has 5:4 aspect ratio. Take this into account when specifying a screen. 

Lens 

 

Throw Distance Formula  

 

 

TL-08SF:

 

H x 0.84 

TL-1ZH:

  

(Wide) = H x 1.5   

(Tele) = H x 2.5 

TL-2Z:

   

(Wide) = H x 2.5   

(Tele) = H x 4.0 

TL-4Z:

   

(Wide) = H x 4.0   

(Tele) = H x 7.0 

 

Note: 

Do not use TL-1Z lens on SX10000, for optimal performance TL-1ZH should be used for 1.5-2.5:1 range.

 

 

Содержание Nighthawk SX10000D

Страница 1: ...or 14 m max TL 2Z Throw Ratio 2 5 4 0 1 F 3 0 Distortion full offset 2 max Screen Sizes 80 500 5 4 Lateral color error 14 m max TL 4Z Throw Ratio 4 0 7 0 1 F 3 0 Distortion full offset 2 max Screen Si...

Страница 2: ...n Distance SF Fixed Lens Zoom Lens TL 08SF TL 1ZH TL 2Z TL 4Z Width W Height V 0 84 1 1 5 2 5 2 5 4 0 4 0 7 0 63 50 4 52 9 94 5 157 5 157 5 252 252 441 75 60 50 4 112 5 187 5 187 5 300 300 525 90 72 7...

Страница 3: ...1 5 2 5 1 range Projection Distance SF Fixed Lens Zoom Lens TL 08SF TL 1ZH TL 2Z TL 4Z Width W Height V 0 84 1 1 5 2 5 2 5 4 0 4 0 7 0 63 50 4 52 9 94 5 157 5 157 5 252 252 441 75 60 50 4 112 5 187 5...

Страница 4: ...p first Normal Position 0 41V Desktop Front Vertical Max Note There is a mechanical limitation to shift down without first shifting right and left without first shifting up Refer to diagram H width of...

Страница 5: ...s a starting point Fixed Lens TL 08SF Maximum Possible Range Up 0 09V Down 0 09V Right 0 06H Left 0 06H Normal Position Max 0 15V Desktop Front Vertical Note There is a mechanical limitation to shift...

Страница 6: ...Ceiling 4 72 4 72 4 72 11 81 1 69 16 02 24 65 8 90 1 69 2 36 14 17 0 315 1 99 32 91 8 M10 L20 Ver 1 6 Page6 Cabinet Dimensions The following drawings show the cabinet dimensions for the SX10000 Dimen...

Страница 7: ...on Data Desktop and Ceiling 2 05 1 69 38 31 26 77 3 21 3 93 0 57 Ver 1 6 Page7 Cabinet Dimensions continued The following drawings show the cabinet dimensions for the SX10000 Dimensions are in inches...

Страница 8: ...7 5 91 4 67 8 19 4 72 Ver 1 6 Page8 Lens Dimensions The following drawings show the lenses mounted on the projector Dimensions are in inches For millimeters multiply by 25 4 TL 2Z 2 5 4 0 1 Zoom Lens...

Страница 9: ...00 00 00 19 LAMP AUTO 03 88 00 00 02 0B 00 98 HIGH BRIGHT 03 88 00 00 02 0B 01 99 VARIABLE 03 88 00 00 02 0B 02 9A PICTURE BRIGHT 03 10 00 00 05 00 FF 00 Lower Upper CKS Adustment Value from FFE1 min...

Страница 10: ...8 bits Parity No parity Stop bit 1 bit X on off None Communication procedure Full duplex Note For cable lengths longer than 20 it is recommended changing baud rate to 9600 bps PC Control Connector D...

Отзывы: