background image

      

 

           Visual Systems 

SX10000 Installation Data 

Desktop and Ceiling

  

 

 

 

 

 

 

 

 

 

Ver 1.6 

             Page4 

 

Lens Shift Adjustable Range 

Lens Shift Adjustable Range for Desktop and Ceiling Application. 
The diagram below shows the location of the image position in the lens. The lens can be shifted within the shaded area as shown 
using the normal projection position as a starting point. 
 

Maximum Possible Range for TL-1ZH, TL-2Z and TL-4Z 

 
Maximum Possible Range: 
Up: 0.41V 
Down:  0.24V (only if image is shifted right first) 
Right: 0.28H 
Left: 

0.19H (only if image is shifted up first) 

 

Normal Position

0.41V

Desktop/Front

Vertical

Max.

Note

: There is a mechanical limitation to shift down without 

first shifting right, and left without first shifting up. (Refer to 
diagram) 
 

H: width of projected image 
V: height of projected image (5:4) 
 

0.28H

0.19H

0.41V

0.24V

Normal Projection

position

 

 
Maximum Possible Range: 
Up: 

0.24V (only of image is shifted left first) 

Down: 0.41V 
Right:  0.19H (only if image is shifted down first) 
Left: 0.28H 
 

0.41V

Normal Position

Ceiling/Front

Vertical

Max.

 

Note:

 There is a mechanical limitation to shift up without first 

shifting left, and right without first shifting down. (Refer to 
diagram) 
 
 
 

H: width of projected image 
V: height of projected image (5:4) 

Normal Projection

0.24V

0.41V

0.28H

0.19H

position

 

 

Содержание Nighthawk SX10000D

Страница 1: ...or 14 m max TL 2Z Throw Ratio 2 5 4 0 1 F 3 0 Distortion full offset 2 max Screen Sizes 80 500 5 4 Lateral color error 14 m max TL 4Z Throw Ratio 4 0 7 0 1 F 3 0 Distortion full offset 2 max Screen Si...

Страница 2: ...n Distance SF Fixed Lens Zoom Lens TL 08SF TL 1ZH TL 2Z TL 4Z Width W Height V 0 84 1 1 5 2 5 2 5 4 0 4 0 7 0 63 50 4 52 9 94 5 157 5 157 5 252 252 441 75 60 50 4 112 5 187 5 187 5 300 300 525 90 72 7...

Страница 3: ...1 5 2 5 1 range Projection Distance SF Fixed Lens Zoom Lens TL 08SF TL 1ZH TL 2Z TL 4Z Width W Height V 0 84 1 1 5 2 5 2 5 4 0 4 0 7 0 63 50 4 52 9 94 5 157 5 157 5 252 252 441 75 60 50 4 112 5 187 5...

Страница 4: ...p first Normal Position 0 41V Desktop Front Vertical Max Note There is a mechanical limitation to shift down without first shifting right and left without first shifting up Refer to diagram H width of...

Страница 5: ...s a starting point Fixed Lens TL 08SF Maximum Possible Range Up 0 09V Down 0 09V Right 0 06H Left 0 06H Normal Position Max 0 15V Desktop Front Vertical Note There is a mechanical limitation to shift...

Страница 6: ...Ceiling 4 72 4 72 4 72 11 81 1 69 16 02 24 65 8 90 1 69 2 36 14 17 0 315 1 99 32 91 8 M10 L20 Ver 1 6 Page6 Cabinet Dimensions The following drawings show the cabinet dimensions for the SX10000 Dimen...

Страница 7: ...on Data Desktop and Ceiling 2 05 1 69 38 31 26 77 3 21 3 93 0 57 Ver 1 6 Page7 Cabinet Dimensions continued The following drawings show the cabinet dimensions for the SX10000 Dimensions are in inches...

Страница 8: ...7 5 91 4 67 8 19 4 72 Ver 1 6 Page8 Lens Dimensions The following drawings show the lenses mounted on the projector Dimensions are in inches For millimeters multiply by 25 4 TL 2Z 2 5 4 0 1 Zoom Lens...

Страница 9: ...00 00 00 19 LAMP AUTO 03 88 00 00 02 0B 00 98 HIGH BRIGHT 03 88 00 00 02 0B 01 99 VARIABLE 03 88 00 00 02 0B 02 9A PICTURE BRIGHT 03 10 00 00 05 00 FF 00 Lower Upper CKS Adustment Value from FFE1 min...

Страница 10: ...8 bits Parity No parity Stop bit 1 bit X on off None Communication procedure Full duplex Note For cable lengths longer than 20 it is recommended changing baud rate to 9600 bps PC Control Connector D...

Отзывы: