4-11
TROUBLESHOOTING
“Confidential, Do Not Duplicate without written authorization from NEC.”
ErrMsg12VOverSpec
When 12V voltage >12.6 or <11.4 and Polling time is 1s.
Check 12V input voltage on slave board or replace power board.
ErrMsgBallast1UartError
When ballast1 communication no response.
Check or replace Ballast1 or slave board.
ErrMsgBallast2UartError
When ballast2 communication no response.
Check or replace Ballast2 or slave board
ErrMsgFanInitError
When AC on make fan to high speed, if it is fail toggle.
When Lamp on make fan to target speed, if it is fail toggle.
Check or replace all Fan Driver boards and Fans.
ErrMsgExGpioFail
When Lamp on process get ExGpio fail.
Check or replace slave board
ErrMsgFan1DriverError - Check or replace Fan Driver D board.
ErrMsgFan2DriverError - Check or replace Fan Driver C board.
ErrMsgFan3DriverError - Check or replace slave board.
ErrMsgFan4DriverError- Check or replace Fan Driver D board.
ErrMsgFan5DriverError- Check or replace Fan Driver D board.
ErrMsgFan6DriverError- Check or replace Fan Driver C board.
ErrMsgFan7DriverError- Check or replace Fan Driver E board
ErrMsgFan8DriverError- Check or replace Fan Driver C board.
ErrMsgFan9DriverError- Check or replace Fan Driver B board.
ErrMsgFan10DriverError- Check or replace Fan Driver B board.
ErrMsgFan11DriverError- Check or replace Fan Driver E board
Содержание NP-NC900C-A