SPECIFICATIONS
Stand by
After cooling T = 90s
blower = X rpm
blower = X rpm
Lamp delay cooling 20s
Turn on lamp
Turn on system
Stand by
0
No Pre-cooling
of blower
stop blower 30s
Avoid condensing
Turn off or
temperature ptotection
Normal condition to turn on lamp.
Fan9/Fan10 operation.
Two worse cases to turn on lamp.
Fan9/Fan10 operation.
Not lit in the end.
1. Delay Cooling for normal situation is 20s; for abnormal (AC off) is 20s; for lamp mode switch from single
lamp to dual lamp is 20s
2. For system fan: After cooling is 90s for all sysytem fans except fan9 and Fan10 (Fan tables of After
Cooling follow the last operating status.)
3. For lamp blower. After cooling blower stop 30s when the lamp be switched off. After 30s blower restart
and continue cooling for 60s.
4. Lamp mode switch from Dual lamp to Lamp1 only, Fan10 stop running right away and follow lamp
blower rule of after cooling. Then, stop the blower.
from Dual lamp to Lamp2 only, Fan9 stop running right away and follow lamp blower rule of after
cooling. Then, stop the blower.
(please lock lamp mode switch function for 90s)
count = 2
count = 3
count = 1
count = 0
failed ignition
Avoid condensing
10s
Interrupt AC then
instant turn on lamp
10s
10s
turn on lamp
turn on lamp
30s
30s
show lamp
error msg
30s
failed ignition
failed ignition