ND-45669 (E)
CHAPTER 3
Page 113
Revision 2.0
CM15
COMMAND CODE
TITLE:
SERVICE RESTRICTION CLASS
15
MAT
Note 1:
The tone indication pattern is assigned by the combination of data in YY=83 and YY = 84
Note 2:
The result of a Switch Hook Flash during a station-to-station call is specified by the combination
of data in YY= 88 and YY = 89.
Note 3:
The result of a Switch Hook Flash during a C.O. line Connection is specified by the combination
of data in YY=90 and YY = 91.
Note 4:
Automatic Allocation is available by Multiline Terminal with LCD for call park-system.
Note 5:
Service for an Off Hook Alarm call which encounters a busy terminating station is specified by
the combination of data in YY=97 and YY = 98
Note 6:
Call Waiting is automatically set, when UCD is not set.
: Initial Data
YY
83
84
MEANING OF DATA
Setting Data
0
0
600 + 700 [Hz]
Modulating Signal
1
0
1024 + 1285 [Hz]/16 [Hz]
Modulating Signal
0
1
480 + 606 [Hz]/8 [Hz]
Modulating Signal
1
1
480 + 606 [Hz]/16 [Hz]
Modulating Signal
: Initial Data
88
89
MEANING OF DATA
1
1
Effective (Special Dial Tone Connection)
0
1
Ineffective
0
0
Attendant Recall
: Initial Data
90
91
MEANING OF DATA
1
1
Effective (Special Dial Tone Connection)
0
1
Ineffective
0
0
Attendant Recall
: Initial Data
97
98
MEANING OF DATA
0
0
UCD - Call Waiting
Note 6
(CM08-212-0)
0
1
UCD
(CM08-212-1)
1
0
Call Waiting
1
1
Hunting
Содержание NEAX 2000 IVS
Страница 1: ...ND 45669 E ISSUE 2 PART OF STOCK 151901 Command Manual DECEMBER 1997 NECAmerica Inc ...
Страница 17: ...CHAPTER 1 ND 45669 E Page 2 Revision 2 0 This page is for your notes ...
Страница 61: ...CHAPTER 2 ND 45669 E Page 44 2 Addendum 001 Revision 2 1 AUGUST 1998 This page is for your notes ...
Страница 77: ...CHAPTER 2 ND 45669 E Page 60 Revision 2 0 This page is for your notes ...
Страница 473: ...CHAPTER 4 ND 45669 E Page 430 Revision 2 0 This page is for your notes ...