INFORMATION FOR DATA PROGRAMMING
(1) Example: When Station Number 300 is to be assigned to LEN 0000 and Station Number 301 to LEN 0001
by CM10 (Refer to
Table 2-3
.)
Note 1:
When no data exists, “NONE” is displayed. And when data exists, that data is displayed.
Note 2:
This
operation is for confirming the data assignment. Thus it may be omitted.
Table 2-3 Assignment Operation
(DISPLAY)
STEP 1 Turn ON power switch.
STEP 2 Press .
STEP 3 Enter “10” (Command Number).
STEP 4 Press .
STEP 5 Enter “0000” (LEN).
STEP 6 Press .
Note 1
STEP 7 Enter “300” (Station Number).
STEP 8 Press .
STEP 9 Press .
Note 2
STEP 10 Press .
Note 1
STEP 11 Enter “301” (Station Number).
STEP 12 Press .
STEP 13 Press .
Note 2
STEP 14 Turn OFF power switch.
_
ST
COMMAND = _
COMMAND = 10 _
DE
10> _
10> 0000_
DE
10> 0000: NONE-_
10> 0000: NONE-300
EXE
OK _
DE
10> 0000: 300-_
S
10> 0001: NONE__
10> 0001: NONE-301
EXE
OK _
DE
10> 001 : 301 _