5. Troubleshooting
Express5800/R120h-1M, R120h-2M (3rd-Gen) Maintenance Guide
32
Chapter 1 Maintenance
5.2
Problem of booting EXPRESSBUILDER
[?]
EXPRESSBUILDER cannot start.
□
Is the system status correct?
→
EXPRESSBUILDER cannot start when the settings of BIOS/iLO are incorrect. To correct the internal
settings, try the following procedure in order.
(a). AC OFF/ON and retry.
(b). Clear the EXPRESS configuration by using PERFORM MAINTENANCE > System Erase and
Reset and retry.
(c). Restore the BIOS settings by using the following and retry.
System Configuration > BIOS/Platform Configuration (RBSU) > System Default Options > Restore
Default Manufacturing Settings
(d). Restore the iLO settings by using the following and retry.
System Configuration > BMC Configuration Utility > Set to factory defaults
[?]
Unable to install the OS or installation fails
□
Is the OS you are trying to install Windows?
→
Only the Windows OS can be installed with EXPRESSBUILDER. For the types of Windows that can be
installed, refer to the
"Installation Guide (Windows)"
.
[?]
System time is off
□
Did you reboot with the upper right icon of EXPRESSBUILDER?
→
If the system is rebooted with the icon, the system time of RBSU may be off by tens of seconds. If this
occurs, set it again with RBSU, etc.