(2) Automatic transmit/receive data setting
(a) Transmit data setting
[1] Write transmit data from the least significant address of buffer RAM, FAC0H (up to FAFFH).
The transmit data should be in the order from higher address to lower address.
[2] Set the automatic data transmit/receive address pointer (ADTP) to the value obtained by
subtracting 1 from the number of transmit data bytes.
(b) Automatic transmit/receive mode setting
[1] Set bit 7 (CSIE1) and bit 5 (ATE) of serial operating mode register 1 (CSIM1) to 1.
[2] Set RE of the automatic data transmit/receive control register (ADTC) to 1.
[3] Set the data transmit/receive transfer interval in the automatic data transmit/receive interval
specification register (ADTI).
[4] Write any value to serial I/O shift register 1 (SIO1) (transfer start trigger).
Caution Writing any value to SIO1 orders the start of an automatic transmit/receive operation;
the written value has no meaning.
The following operations are automatically carried out when (a) and (b) are carried out.
•
After the buffer RAM data specified by ADTP is transferred to SIO1, transmission is carried
out (start of automatic transmission/reception).
•
The received data is written to the buffer RAM address specified by ADTP.
•
ADTP is decremented and the next data transmission/reception is carried out. Data
transmission/reception continues until the ADTP decremental output becomes 00H and the
data of address FAC0H is output (end of automatic transmission/reception).
•
When automatic transmission/reception is terminated, bit 3 (TRF) of ADTC is cleared to 0.