- 32 -
3.2 Connection of SAS Cable
An SAS cable is used to connect the Autoloader to a server or workstation. The SAS
connector is on the rear side of the Autoloader.
After connecting the SAS cable, be sure to attach the terminating resistance connector that is
provided with the unit. The Autoloader will not operate correctly unless this terminating
resistance connector is attached.
For instructions on how to connect to the server or workstation, see the documents provided
with the server or workstation.
Caution:
After connecting the cable, make sure it is connected securely.
The SAS cable's connector includes a locking mechanism.
Make sure it is set to the locked position.
3.3 Connection of AC Power Cable
After connecting the signal cable, make sure that the power switch is in the OFF position.
After confirming that the power is OFF, insert the AC power cable's plug into the Autoloader's
AC power connector. Make sure that the plug is fully inserted.
Check that the AC power cable to be connected meets the following requirements before
using it.
•
Must be safety certified in the country where it will be used
•
Maximum voltage must match or exceed the power supply voltage to be used.
•
Rated current must be at least 7 A.
•
Length must be no more than 3 m.
•
Triplex, double-insulated (double sheathed)
Содержание LL009F
Страница 37: ... 37 ...
Страница 63: ... 63 Java Settings in Internet Explorer ...
Страница 83: ... 83 Example when inventory is in progress Normal end ...
Страница 90: ... 90 Window image Loader Mode setup window 1 2 3 ...
Страница 92: ... 92 Window image Network setup window 1 3 2 4 ...
Страница 94: ... 94 Window image Date and Time setup window 3 2 1 ...
Страница 96: ... 96 Window image Event Notifications setup window email 5 6 1 2 3 4 7 ...
Страница 98: ... 98 Window image Event Notifications setup window SNMP 5 6 1 3 4 7 8 2 9 ...