50
6.4
Connect Power and Data Cables to Power Bar
This section is a guide to power and data connection in the Power bar.
Warning!
Only trained personnel, such as electricians or NEC personnel, may
connect the internal power supply to mains power supply.
Table 10: Cable Connection Requirements
No. of People
1
Prerequisites
Cabinets securely installed
Tools
Screwdriver
Equipment
External power cable (not included in delivery)
Data cables from LED Wall to NovaStar Controller (Cat cable, FTP Cat5e)
Figure 57: Connections in Power Bar
A External power input
C1 Ethernet port main data
B Terminal in Power bar
C2 Ethernet port backup data
C Network and supply socket in Power bar
D1 Data cable main
D2 Data cable backup
Connect Data Cables to the Power Bar
6.4.1
Prepare the data connection according to the cabling plans, see 15.1 Cable Plans.
Step 1)
Each column of cabinets needs one main and one backup data input.
Connect the main data input to the left Ethernet ports and the backup data input to the
Step 2)
right Ethernet ports in the Power bar. See also Figure 57.
C
C1
B
C2
A
D1
D2
L
L
PE
N
N
PE
Содержание LED-FA025i2-220
Страница 61: ...61 Figure 78 Screen Settings for 8 8 Controller...
Страница 91: ...91 Part Name AC terminal Hub For 0 9 mm only CAT cable Mask For 1 5 1 9 2 5 3 8 mm only...
Страница 96: ...96 LED FA015i2 137 Data Connections 15 1 3 LED FA015i2 137 Power Connections 15 1 4...
Страница 97: ...97 LED FA019i2 165 Data Connections 15 1 5 LED FA019i2 165 Power Connections 15 1 6...
Страница 99: ...99 LED FA012i2 220 Data Connections 15 1 9 LED FA012i2 220 Power Connections 15 1 10...