32
Receiving Cards
Receiving cards process the data from the Sending card (external NovaStar Controller) and
distribute the signal to the Pixel cards. The Receiving cards work redundantly. In case of failure of
one Receiving card, the other Receiving card provides the picture.
Figure 28: Redundant Receiving Cards
Power Supply
3.5.5
In each module, two redundant Power supply units (PSU) connect through a Power distribution
unit (PDU) to run in parallel, where each deliver half of the required power. This mechanism
provides power and sufficient reserve. In a case of failure of one or the other unit, the functional
PSU can be delivered in full power from the remaining unit. In rare cases, where both PSUs are
defective, the Power supply units of the module have to be replaced.
The following components contribute to the power supply of a module:
2 Power supply units (PSU) (A)
1 Power distribution unit (PDU) (B1) with PDU shielding (B2): The PDU shielding protects the
high voltage components from being touched by accident. Do not remove while power is
connected!
2 Power supply interfaces to Hub board (C): Counter-part to the Hub board's four pin
connectors to supply the Hub board with power.
Figure 29: Behind Hub Board – Redundant Power Supply with Wired PDU with PDU Shielding
B2
B1
B
A
C
Содержание LED-FA025i2-220
Страница 61: ...61 Figure 78 Screen Settings for 8 8 Controller...
Страница 91: ...91 Part Name AC terminal Hub For 0 9 mm only CAT cable Mask For 1 5 1 9 2 5 3 8 mm only...
Страница 96: ...96 LED FA015i2 137 Data Connections 15 1 3 LED FA015i2 137 Power Connections 15 1 4...
Страница 97: ...97 LED FA019i2 165 Data Connections 15 1 5 LED FA019i2 165 Power Connections 15 1 6...
Страница 99: ...99 LED FA012i2 220 Data Connections 15 1 9 LED FA012i2 220 Power Connections 15 1 10...