Upgrading Your System 4-11
Installing DIMMs
1.
Observe the safety and ESD precautions listed under
General Information
and
Static Precautions
at the beginning of this chapter.
2.
Perform the steps in "Preparing Your System for Upgrade" described earlier
in this chapter.
3.
Extend the server out from the rack.
4.
Remove the top cover of the system chassis. See
Top Cover Removal
found
earlier in this chapter.
!
CAUTION
For proper cooling and airflow, do not operate the system
with the top cover removed. Always
replace
the top cover
before powering on the system.
4.
Locate the appropriate DIMM sockets on the system board (see
Figure 4-7).
5.
If present, remove the DIMM connector cover from its socket
(see Figure 4-8). Save the DIMM connector cover for future use.
Note:
If you are replacing a DIMM, you must first
remove the DIMM from its socket (see
Removing DIMMs
later in this chapter).
Figure 4-8. Removing the DIMM Connector Cover
6.
Holding a DIMM module only by the edges, remove it from its antistatic
package.
!
CAUTION
Observe static precautions. Use an antistatic wrist strap.
Hold the DIMM only by its edges.
7.
Position the DIMM so that the two notches in the bottom edge of the DIMM
align with the keyed socket. See Figure 4-9.
Содержание Express5800/120Rf-2
Страница 1: ... U s e r s G u i d e EXPRESS5800 120Rf 2 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...viii Contents ...
Страница 61: ...Setting Up the System 2 29 Figure 2 34 Making Connections ...
Страница 80: ......
Страница 186: ...5 22 Problem Solving ...
Страница 187: ...A Specifications System Specifications ...
Страница 197: ...C Interrupt Requests ...
Страница 199: ...Interrupt Requests C 3 ...
Страница 209: ...10 Glossary ...
Страница 214: ...xx ...
Страница 215: ... 456 01669 000 ...