4-22 Configuring Your Server
Option
Parameter
Description
Your Setting
Boot Monitoring
Policy
[Retry 3 Times]
Retry Service Boot
Always Reset
Specify the processing at the
occurrence of timeout during boot
monitoring.
If [Retry 3 times] is selected, the
system is reset after the
occurrence of timeout and OS boot
is retried up to three times.
If [Retry Service Boot] is selected,
the system is reset after the
occurrence of timeout and OS boot
is retried up to three times. Then
the boot is tried from the service
partition for three times. The failure
in the third boot causes the system
to stop booting.
If [Always Reset] is selected, the
system is reset after the
occurrence of timeout and OS boot
is retried repeatedly.
* If no service partition exists in
the system, OS boot is retried
repeatedly from the system
partition.
Thermal Sensor
Disabled
[Enabled]
Specify whether to enable or
disable the thermal sensor
monitoring function. If a thermal
error is detected with this item
being set to "Enabled", the system
stops at the end of POST.
BMC IRQ
Disabled
[IRQ 11]
Set the IRQ for BMC.
Post Error Pause
Disabled
[Enabled]
Indicates whether POST is aborted
once at the end of POST if an error
occurs during the execution of
POST.
AC-LINK
Stay Off
[Last State]
Power On
Specify the state of power when
the AC power to the server is
turned off once and then on. (See
the table below.)
Power on Delay
Time
[0] - 255
Specify the DC power on delay
time within the range between 0
and 255 seconds. The time
specified is valid when "Power On"
or "Last State" is specified for AC
LINK.
Platform Event
Filtering
Disabled
[Enabled]
This item becomes meaningless
when the notification feature of
EXPRESSSCOPE Engine is
enabled.
[ ]: Factory-set
Содержание Express5800 120Li
Страница 16: ...x This page is intentionally left blank ...
Страница 32: ...2 4 General Description Front View Door Opened 1 2 DVD ROM Drive 1 2 5 6 7 8 6 4 9 3 10 2 1 2 2 2 3 2 4 ...
Страница 37: ...General Description 2 9 MOTHER BOARD 1 2 3 4 5 6 7 22 9 10 11 12 13 14 15 16 17 23 21 8 20 19 18 24 25 26 ...
Страница 54: ...2 26 General Description This page is intentionally left blank ...
Страница 180: ...7 12 Maintenance This page is intentionally left blank ...
Страница 214: ...8 34 Troubleshooting This page is intentionally left blank ...
Страница 277: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Страница 286: ...10 10 Internal Cabling Diagrams This page is intentionally left blank ...
Страница 344: ...F 4 Product Configuration Record Table This page is intentionally left blank ...