Configuring Your Server 4-45
Check Consistency
Run LSI Logic Software RAID Setup Utility
Perform Check Consistency
Exit LSI Logic Software RAID Setup Utility
1.
Run LSI Logic Software RAID Setup Utility.
2.
Select "Check Consistency" from the TOP menu.
The "Logical Drives" screen appears.
3.
Move the cursor onto the logical drive to be checked, and press
Space
to select it.
4.
When logical drive has been selected, press
F10
to start consistency check.
5.
A confirmation screen for execution appears. Select "Yes".
The consistency check starts.
When the progress bar in the "Check Consistency Progress" screen indicates 100%, the
consistency check is completed.
6.
Press
Esc
to return to the TOP menu and exit LSI Logic Software RAID Setup Utility.
IMPORTANT:
Be sure to execute Check Consistency after creating configuration.
Check Consistency has two modes: "check and recover" and "check
only".
Содержание Express5800 120Li
Страница 16: ...x This page is intentionally left blank ...
Страница 32: ...2 4 General Description Front View Door Opened 1 2 DVD ROM Drive 1 2 5 6 7 8 6 4 9 3 10 2 1 2 2 2 3 2 4 ...
Страница 37: ...General Description 2 9 MOTHER BOARD 1 2 3 4 5 6 7 22 9 10 11 12 13 14 15 16 17 23 21 8 20 19 18 24 25 26 ...
Страница 54: ...2 26 General Description This page is intentionally left blank ...
Страница 180: ...7 12 Maintenance This page is intentionally left blank ...
Страница 214: ...8 34 Troubleshooting This page is intentionally left blank ...
Страница 277: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Страница 286: ...10 10 Internal Cabling Diagrams This page is intentionally left blank ...
Страница 344: ...F 4 Product Configuration Record Table This page is intentionally left blank ...