![NEC EXP339 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/nec/exp339/exp339_user-manual_4209561028.webp)
4. Names and Functions of Parts
Express5800/T110j User’s Guide
28
Chapter 1 General Description
STATUS LED 1, 2 pattern
Description
Action
STATUS LED 1 STATUS LED 2
On (green)
Off
The server is operating normally.
–
On (green)
On (amber)
Initialization of BMC is in progress.
Wait until initialization completes.
Blinking (green)
Off
Memory is in a degraded state
Find the device in degraded state by using
BIOS Setup Utility (SETUP), and replace it as
soon as possible.
In redundant power configuration, power is
not supplied to either of power unit.
Off
Off
The power is off.
Turn on the server.
Watchdog timer expired.
Turn off the power and then turn it on.
If POST displays any error message, take
notes of the message, and contact your sales
representative.
Memory dump is being requested.
Note: The LED remains green if the dump is
caused by software.
Wait until the memory dump is completed.
Off
On (amber)
A temperature alarm was detected.
Check the internal fan for dusts. Also check if
the fan unit is properly connected.
A CPU error occurred.
Turn off the power and then turn it on.
If POST displays any error message, take
notes of the message, and contact your sales
representative.
A PCI system error occurred
A PCI parity error occurred
A PCI bus error occurred.
A voltage alarm was detected.
Contact your sales representative.
A CPU temperature alarm was detected.
A correctable memory error has often
occurred.
It is recommended to replace to new memory
as soon as possible.
An error occurred on Intel Node Manager
(one of the features of BMC Management
Console).
Contact your sales representative.
SEL area becomes full (1024 records)
Clear the SEL by Server Configuration Utility,
BMC Management Console or NEC ESMPRO
Manager.
Off
Blinking (amber) Power Supply Unit is failing (in power
redundant configuration).
Contact your sales representative.
A fan alarm was detected.
Check if the internal fan cable is properly
connected.
A temperature warning was detected.
Check the internal fan for dusts. Also check if
the fan unit is properly connected.
A voltage warning was detected
Contact your sales representative.
One or more hard disk drives are
failing.(Only RAID system configuration with
2.5/3.5HDD hot-plug cage)
SEL area becomes 75% full (768 records)
Clear the SEL by Server Configuration Utility,
BMC Management Console or NEC ESMPRO
Manager.
Содержание EXP339
Страница 127: ...MEMO...