3-12
Installing Server
Unmounting the Device from the Rack (N8140-74/92/93/94/98/99)
Follow the steps below and unmount the device from the rack.
CAUTION
Observe the following precautions to use the server safely. There is a risk of a
burn, personal injury, or damage to physical assets. For details, see
“
Notes for
Safe Handling
“
in Chapter 1.
Do not carry or install a rack alone.
Do not squeeze your fingers in the product
Do not impose a weight on the device when it is pulled out from the rack.
Do not pull a device out of the rack if the rack is unstable.
Do not leave more than one device pulled out from the rack.
Do not pull the device from the rack while it is operating.
1.
Check that the device is powered off, and remove all the power cords and interface cables that
are connected to the device.
2.
Remove the front bezel.
3.
Loosen the screws on the left and right sides of the front panel of the CPU/IO module and
release the lock by pulling the ejector toward you.
4.
Pull out the CPU/IO module gently from the rack.
IMPORTANT:
-
When you pull out the device, do not load anything on its top. It is dangerous, since the
device becomes unstable and it may fall.
-
Do not hold the handle on the front side or the convex part on the back side. To move
the device, hold the bottom.
-
Since the device is locked and can not be pulled out, pull it out after releasing the lock
by lowering the lock on the side of the CPU/IO module.
5.
Hold tightly when you unmount 4U chassis from the rack,.
To remove the mechanical parts of the rack, see the installation procedure.
Содержание EXP320K
Страница 11: ......
Страница 18: ...1 2 Before Using 在使用前 為了把本裝置做為安全確實變成使用必要的關於信息 實體及附屬品等記載著 在安裝實體之前 必定 請讀 同時 關於本文中的名稱請參照用戶指南的 與各部分的名稱功能 的項 ...
Страница 38: ...1 22 Before Using This page is intentionally left blank ...
Страница 70: ...4 10 ESX Server Setup 9 Move the cursor onto Embedded SAS Option ROM and press Enter Parameters appear ...
Страница 77: ...ESX Server Setup 4 17 1 4 Select Enable or Disable BIOS 1 5 Select 1 so that Enabled is configured ...
Страница 79: ...ESX Server Setup 4 19 1 8 Select the location for Boot Entry select 1 1 9 Select the boot device select 01 ...
Страница 80: ...4 20 ESX Server Setup 1 10 Enter LUN Hex select 00 1 11 Select Boot LUN select 01 ...
Страница 108: ...5 16 Procedures after Completion of Installation This page is intentionally left blank ...
Страница 112: ...6 4 Troubleshooting This page is intentionally left blank ...
Страница 114: ......
Страница 115: ......