6 - 169
___________________________________________________________________________________
___________________________________________________________________________________
A maximum of 22 IAD(8)-U( ) ETUs can be installed in slots S1~S8
when used as a
CCISoIP
ETU.
8.8.4
Switch Settings
Refer to
Table 6-64 IAD(8)-U( ) ETU Switches
Unlike the IPK system, DIP switch S2-4 should not be ON. It is not
required for card recognition and may interfere with normal operation.
8.8.5
Ethernet Status
Two Built-in LEDs (One green and one yellow) on the front of each
RJ-45 Connector indicate Ethernet connection status. The yellow
LED is On when the link is up; the green LED is On to indicate
activity.
8.8.6
Connectors
The following connectors are included:
J
P1
Connects to the backplane.
J
J1, J10, J11
Reserved for future use.
J
J5
RJ-45 Ethernet connector for future use
J
J6
Default RJ-45 Ethernet connector
Table 6-64
IAD(8)-U( ) ETU
Switches
Switch
Setting
Description
S1
Press to Reset
Host Reset Switch
S2
Shown below
Eight-position DIP Switch
S2-1~4
Always Off
Reserved
S2-5
Always On to enable
eight ports
(Off enables four ports)
Number of Voice Ports Selection
S2-6~-8
S2-8 On for CCISoIP
mode.
S2-6 On for ESI Mode
IAD(8)-U( ) ETU
Mode
Selection to show simulated ETU
Содержание ELECTRA ELITE IPK II
Страница 2: ......
Страница 3: ...SYSTEM HARDWARE MANUAL INT 1076 IPK II DOCUMENT REVISION 3 VERSION 2000...
Страница 4: ......
Страница 6: ......
Страница 10: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 641: ...SYSTEM HARDWARE MANUAL NECUnified Solutions Inc Document Revision 3...
Страница 642: ......