Installing ETUs (Circuit Cards)
___________________________________________________________________________________
Document Revision 3
Electra Elite IPK II
7.6.2
Installation
The VMS(2)-U10 ETU has two channels of built-in Voice Mail.
The VMS(4)-U10 ETU has four channels of built-in Voice Mail.
The VMS(8)-U10 ETU has eight channels of built-in Voice Mail.
Basic Port Package
Only one VMS(2)/(4)/(8)-U( ) ETU or one VMS-U30 ETU can be
installed in each system in slots S1~S8.
This ETU shares the total number of station ports in the system.
Expanded Port Package
Only one VMS(2)/(4)/(8)-U( ) ETU or one VMS-U30 ETU can be
installed in each system in slots S1~S8.
This ETU shares the total number of station ports in the system.
Each system can support only one CMS, CTI/VP, CTP, FMS, VMS,
or VMP ETU.
7.6.3
Switch Settings
Refer to
Table 6-47 VMS(2)/(4)/(8)-U( ) ETU DIP Switch Settings
.
(Revision Q30931 v 6.65 or lower). For Revision Q30931 v 6.68 or
higher, refer to
Table 6-48 VMS(2)/(4)/(8)-U( ) ETU DIP Switch
Table 6-47 VMS(2)/(4)/(8)-U( ) ETU DIP Switch Settings
Switch
Description
1
Normally Off.
(On to enable COM1.)
2
Normally Off.
When 1 and 2 are both On, COM1 is enabled for HOSTKEY
and the VM application is stopped for Maintenance.
3
On to enable COM2 for remote RS-232/RJ-11.
Off to allow COM1 local connection.
4
Not Used.
Used for Revision Q30931 v 6.65 or lower.
When installing this ETU, make all ETU DIP switch setting
changes before inserting it in the KSU. Ensure that the
KSU is off.
Содержание ELECTRA ELITE IPK II
Страница 2: ......
Страница 3: ...SYSTEM HARDWARE MANUAL INT 1076 IPK II DOCUMENT REVISION 3 VERSION 2000...
Страница 4: ......
Страница 6: ......
Страница 10: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 641: ...SYSTEM HARDWARE MANUAL NECUnified Solutions Inc Document Revision 3...
Страница 642: ......