55
NeoFace Access Control User's Guide
Chapter 2 Installation and Connection
3.
(3)
Installation Environmental Conditions
Places suitable for the installation of
NeoFace
is as follows.
NeoFace
can be used under the following installation environment conditions.
NeoFace
is recommended to be installed such that there is no reflection on the camera image due to sunlight, sunset, and ceiling
lamps.
Items
Installation Environmental Conditions
Ambient temperature
5 to 45
℃
Storage temperature
-20 to 60
℃
Ambient humidity (non-
condensing)
20 to 85%
Storage temperature range
5 to 95%
Air borne dust
Should not be too dusty [0.3mg/m
3
]
JEITA IT-1004 A class B
Conductive and hygroscopic dust should not be present
IP54 compatible *1
Corrosive gas
Should be an environment gas is not detected
JEITA IT-1004 A class A
Earthquake resistance
Continuous
2.0m/s
2
Short time 4.9m/s
2
JEITA IT-1004 A classB
Impact resistance (XYZ)
Electricity ON 19.6 m/s
2
Electricity OFF 98 m/s
2
Power supply voltage
AC100 to 240V ±10%
(
AC90 to 264V
)
※2
Power supply frequency
50 / 60 Hz ± 3Hz
Power supply noise
1kVP-P 50ns to
1μs pulse
Insulation resistance
30MΩ
(
DC500V
)
Insulation withstand voltage
3.0 kV AC 1 minute
Leak current
Less than or equal to 1mA
Electrostatic yield strength
±6 kV (Contact discharge), ±8 kV (Air discharge)
Momentary power failure
Less than or equal to 30ms (at rated voltage)
Grounding
Class D
Others
IP54 compatible *1
*1 Do not use the optional AC adapter outdoors without dust and water proof measures.
When using the AC adapter outdoors, take adequate measures such as placing in a dust proof/waterproof cabinet
avoiding exposure to direct sunlight and rainwater.
*2 The power cord that is connected to the optional AC adapter cannot be plugged into the 200 V AC electric outlet.
Connect to a 100 V AC outlet.