external mains power supply charging check (GOLD series
only)
1.
Keep the engine off and connect the power supply.
2.
the led, related to the power supply, starts to flash
3. Check with the current CLAMP METER that there is a charge
current GOING TO the service battery.
on-off (0-1) switch
The switch on the device must always be left in the ON position
(1), for normal operation.
If the switch is set to OFF (0), the
power
service
is disabled only
from the "Alternator" charge source, then it continues to
operate from the solar panel and / or 230V mains (for the GOLD
model), but it will not work while the engine is running. The
switch should be set to OFF (0) only if the device malfunctions,
disconnecting it when the engine is switched on, and allowing
the battery to be charged using the alternator directly, using
the original system.