problem
potential causes
some unexpected Electronic
device malfunction
service battery high voltage
(higher then 15V)
Solution
we suggest to avoid the desulphation phase selecting the C o D
charging curve.
problem
potential causes
the alternator led flash 6 times
•
detected voltage drop on the
alternator
•
alternator insufficient power
•
power component overheating
•
power loss on the cables
Solution
1. cables must have 10
mm
2
(min) section.
2. check the connections on terminals 1,2,3 and 6.
3. connect the cable attached to terminal 1 directly to the negative
pole of the engine battery (or services),
4. cable attached to terminal 2 directly to the negative pole of the
service battery (or motor),
5. the cable relative to terminal 3 to the positive pole of the engine
battery, or positive pole of the alternator
6. the cable relative to terminal 6 to the positive pole of the service
battery.
in case of overheating of the power components of the
electronic board, the system automatically reduces the
current supplied for charging, until the alarm returns.
Содержание POWERSERVICE PLUS 25