Maintenance Instructions
Adjustments
4-36
NCR 5635 Spray Currency Dispenser Service Manual
NCR - CONFIDENTIAL AND PROPRIETARY
Use pursuant to Company Instructions
Adjustments
4
The adjustments to the dispenser are the Pick Module timing and
the Dispenser Motor drive belt tension.
Pick Module Timing
4
Pick modules on the 5635 Dispenser are known as the Aria pick
modules. The gear trains of the Aria pick modules lock them
together in a fixed timing relationship so that the timing must be set
as the dispenser is assembled as described in the following sections.
The 5635 Spray Currency Dispenser is built in the following
configurations:
In a correctly timed dispenser, when the number 1 on the timing
disk of the top pick module is alongside the timing sensor, then the
number 2 of the second pick module should be alongside its sensor,
the number 3 on the timing disk of the third pick module should be
alongside its sensor, and the number 4 on the timing disk of the
fourth pick module should be alongside its sensor.
Once set, this setting would only change because of a mechanical
failure such as a broken timing belt or stripped gear. The following
sections describe the timing checks necessary when building up the
dispenser after separation because of such a failure.
1 High Dispenser
2 High Dispenser
3 High Dispenser
4 High Dispenser
Presenter
Presenter
Presenter
Presenter
P1 Timing Disk = 1
P2 Timing Disk = 1
P2 Timing Disk = 1
P2 Timing Disk = 1
Timing Disk = 2
Timing Disk = 2
Timing Disk = 2
P1 Timing Disk = 3
P2 Timing Disk = 3
Timing Disk = 4
P1 = Single Pick Module
P2 = Double Pick Module
master.bk Page 36 Wednesday, March 27, 2002 9:35 AM