13
EN
ENGLISH
UNDERSTANDING THE CONTROL BOARD
CONTROL
DESCRIPTION
FC
Actual
MP1
IGNITOR
NO
PELLET
Set
PRIME
F/C
150
175
120
110
205
230
245
SMOKE
OFF
HIGH
95
The LCD Screen is used as the information center for your unit. The
LCD screen will display the current grill temperature (ACTUAL) and
meat probe temperature (MP1). The flashing LCD screen indicates
the unit was just connected to AC power. Screen flashes three
times, then turns off.
Indicates the meat probe temperature when probe is connected.
Indicates the current temperature of unit.
Indicates the desired temperature that has been selected.
Indicates the auger motor is turning and feeding pellets to the
Burn Pot.
Indicates the igniter is on. When first starting your unit, the
igniter runs continuously for the start-up cycle.
Indicates the fan is running. If the grill is in operation, the fan is on.
NO
PELLET
Indicates the auger motor is no longer able to feed pellets to the
Burn Pot. Likely, the hopper is empty and requires refilling.
PRIME
Press and hold the Prime Button to activate an extra feed of pellets to the Burn Pot. This can be used to add more
fuel to the fire just before opening the barrel lid, resulting in a quicker heat recovery time. It can also be used to add
more fuel while smoking, to increase the intensity of clean smoke flavor. Overfeeding the Burn Pot may damage to
grill barrel paint.
F/C
The Temperature Switch Button is used to change the temperature readout on the LED Screen. Press the button to
switch to Fahrenheit (ºF) or to Celsius (ºC), as preferred. Default is set to Celsius.
The Temperature Control Dial allows you to set your desired temperature. Rotate the knob marker to select from
Smoke, any of the eight temperature presets, or High. Once rotating the dial, the SET Temperature on the LCD Screen
will adjust.
OFF
The Off Setting on the Temperature Control Dial is the OFF mode for the unit. The unit will not function on this
setting.
SMOKE
The Smoke Setting on the Temperature Control Dial is the lowest smoking mode for the unit. The grill operates at the
lowest temperature, without the fire going out.
HIGH
The High Setting on the Temperature Control Dial is the highest heat level for the unit. The grill operates at the highest
temperature. When the lid is open, the grill will run at this speed to compensate for the loss of heat in the barrel.
The plug-in connection port on the front of the Control Board is for a Meat Probe. When the meat probe is connected,
the temperature is displayed on the LCD Screen. When the meat probe is not in use, disconnect the adapter from the
connection port.
FC
Actual
MP1
IGNITOR
NO
PELLET
Set
PRIME
F/C
150
175
120
110
205
230
245
SMOKE
OFF
HIGH
95
Содержание PIT BOSS PB150PPS