4.9.16 Water Pressure Sensor
Part
Check Point
Function
They are suitable for analyzing water pressure ratios in heating.
Failure Event
Unable to detect or measure to change water pressure
Effects
Water filling system does not operate automatically
Error Code
E351, E352, E353
Diagnostic
1.
Visual inspection: check the circulation pump connection wire.
2.
Voltage check: Check range of voltage shown below.
Color/Number of wires
Black-Red : DC 0~5V
Legend to cross-section drawing
1. Pressure connection
2. Ceramic sensor
3. Amplifier electronics
4. Cover
5. Electrical connection (RAST 2.5)