Chapter8. CDU Service Manual
8-8
© 2016
Nautilus Hyosung Inc.
All Rights Reserved.
Returning Path Sensor
► CS1D(A,B) / CS15D(A,B) / CS31D(A,B)/ CS41D(A,B)
1. Remove the sensor bracket M4 screws (2 places each) as shown in the figure
below.
2. Remove the connector and the cable tie to remove the sensor bracket. Be careful
not to break the connector pin when removing.
3. Remove the sensor bracket.
4. From the removed sensor bracket, remove the M3 sensor screws (1 place each) of
the sensor which will be replaced.
5. Replace the sensor.
6. Assemble the unit in the reverse order - 4~1.
CS41AD
CS41BD