Vector-LP Radio Beacon Transmitter Technical Instruction Manual
Page
3-35
Section 3 Operating Instructions
Issue 1.1
3.6.14.2 SETTING MONITOR POINTS
Set the site interface PWB’s monitor points
as follows:
(a) Use
f
and
g
to highlight the desired
monitor point (1 through 16). Press
Toggle
to change the logic level (0 or
1) of the
Default
value. The logic level
determines the active (for status
outputs) or normal (for alarm outputs)
state for the monitor point’s remote
output.
NOTE
Monitor points 1 through 16 correspond to
outputs connected to
MONITOR POINT 1
through
16
on TB1 and TB2 of the site
interface PWB.
(b) The values in the
Current
column
represent the existing state of the
monitor point. Press
Set Current
to
set the
Current
values to match the
Default
values.
(c) Return to previous menu by pressing
Back
.
3.6.14.3 SERIAL SETTINGS
Set up the serial connection as follows:
(a) Use
f
and
g
to highlight the desired
serial setting. Press
Modify
or
Toggle
to change the setting. Press
Next
or
Done
when complete.
x
To modify Tx Address, use
f
and
g
.
x
Press
Toggle
to set Connection Mode
to
DIRECT
or
MODEM
. When
MODEM
is selected, the following
screen appears, which enables three
further settings:
x
Press
Toggle
to set Modem Line to
DIAL UP
or
LEASED
. The Dial-up
number option disappears when
LEASED
is selected.
x
Press
f
,
g
and
Next
to set the
Passkey and the Dial-up Number.
(b) Return to the previous menu by
pressing
Back
.
3.6.14.4 AUTOMATIC REPORTING
Configure the serial connection to
automatically report transmitter alarms
(without needing to poll the status) as
follows:
(a) A list of transmitter alarms and their
current Automatic Reporting status is
displayed.
x
To configure an alarm for automatic
reporting, use
f
and
g
to select the
desired alarm and press
Select
to
change the status to
ON
.
Main Menu
Modify
Back
12:43:16 Power: 0W Side A Bypass
Serial Settings
Tx Address
Connection Mode
ABCD
[DIRECT ]
Main Menu
Modify
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Serial Settings
Tx Address
Connection Mode
ABCD
[DIRECT ]
Main Menu
Toggle
Back
12:43:16 Power: 0W Side A Bypass
Serial Settings
Tx Address
Connection Mode
Modem Line
Passkey
Dial-up Number
ABCD
[MODEM ]
[DIAL UP]
0000
Main Menu
Toggle
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Serial Settings
Tx Address
Connection Mode
Modem Line
Passkey
Dial-up Number
ABCD
[MODEM ]
[DIAL UP]
0000
Fault
Automatic Reporting
PDM Latch B
OFF
PDM Latch A
OFF
High RF Current
OFF
SWR Shutback
OFF
Low AC Volts
OFF
Main Menu
Select
Back
12:43:16 Power: 0W Side A Bypass
Fault
Automatic Reporting
PDM Latch B
OFF
PDM Latch A
OFF
High RF Current
OFF
SWR Shutback
OFF
Low AC Volts
OFF
Main Menu
Select
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Monitor Points
Default
Current
Monitor Point 1
0
0
Monitor Point 2
0
0
Monitor Point 3
0
0
Monitor Point 4
0
0
Monitor Point 5
0
0
Set Current
Toggle
Back
12:43:16 Power: 0W Side A Bypass
Monitor Points
Default
Current
Monitor Point 1
0
0
Monitor Point 2
0
0
Monitor Point 3
0
0
Monitor Point 4
0
0
Monitor Point 5
0
0
Set Current
Toggle
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass