3.6.13.6 CHECKING MODULES:
Check the software revision of various
modules that contain microcontrollers as
follows:
(a) Use
f
and
g
to scroll through rows 1
to 12, noting:
x
Rows 0 through 7 are assigned to RF
power modules.
x
Rows 8 and 9 are assigned to the
exciter/monitor generator PWBs (side
A and, if applicable, side B).
x
Row 10 is assigned to the associated
ATUs control/monitor PWB.
x
Row 11 is assigned to the site control
PWB, if installed.
NOTE
If text is not displayed for a particular row,
the associated module or PWB is not
installed.
3.6.14 Remote Control Monitor
System Settings
If the NDB site interface PWB (A4) is
installed, configure the active logic states of
the control and monitor points as follows:
(a) From the main menu, highlight
RCMS
Settings
and press
Select
.
(b) Set the transmitter to
Local
mode.
(c) Press
f
or
g
to scroll through the
options and press
Select
to enter the
appropriate sub-menu (see paragraphs
3.6.14.1 through 3.6.14.3).
x
Control Points (see 3.6.14.1)
x
Monitor Points (see 3.6.14.2)
x
Serial Settings (see 3.6.14.3)
x
Automatic Reporting (see 3.6.14.4)
3.6.14.1 SETTING CONTROL POINTS
Set the site interface PWBs control points
as follows:
(a) Use
f
and
g
to highlight the desired
control point (1 through 16). Press
Toggle
to change the logic level (0 or
1) of the
Set Value
. The logic level
determines the active state for the
control point’s remote input.
NOTE
Control points 1 through 16 correspond to
inputs connected to
CONTROL POINT 1
through
16
on TB3 of the remote control/
monitor interface PWB.
(b) Return to previous menu by pressing
Back
.
Main Menu
Select
Back
12:43:16 Power: 0W Side A Bypass
RCMS Settings
Control Points
Monitor Points
Serial Setting
Automatic Reporting
Main Menu
Select
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
RCMS Settings
Control Points
Monitor Points
Serial Setting
Automatic Reporting
Control Points
Set Value
Control Point 1
0
Control Point 2
0
Control Point 3
0
Control Point 4
0
Control Point 5
0
Toggle
Back
12:43:16 Power: 0W Side A Bypass
Control Points
Set Value
Control Point 1
0
Control Point 2
0
Control Point 3
0
Control Point 4
0
Control Point 5
0
Toggle
Back
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Select
Meters
12:43:16 Power: 0W Side A Bypass
Main Menu
Changeover Control
Events Log
Settings
Peripherals
RCMS Settings
Vector NDB HP
rev 1. 0. 1. 2
Apr 24 2007
15:17:38
Nautel
Select
Meters
12:43:16 Power: 0W Side A Bypass
12:43:16 Power: 0W Side A Bypass
Main Menu
Changeover Control
Events Log
Settings
Peripherals
RCMS Settings
Vector NDB HP
rev 1. 0. 1. 2
Apr 24 2007
15:17:38
Nautel
Module Check
7
8
NAPE76u
rev 0.
0.
0.
2
9
NAPE76u
rev 0.
0.
0.
2
10
11
NAPI80u
rev 0.
1.
0. 34
Main Menu
Select
Back
12:43:16 Power: 0W Site A Bypass
Module Check
7
8
NAPE76u
rev 0.
0.
0.
2
9
NAPE76u
rev 0.
0.
0.
2
10
11
NAPI80u
rev 0.
1.
0. 34
Main Menu
Select
Back
12:43:16 Power: 0W Site A Bypass
12:43:16 Power: 0W Site A Bypass