Vector-LP Radio Beacon Transmitter Technical Instruction Manual
Page
3-15
Section 3 Operating Instructions
Issue 1.1
Table 3-7:
Miscellaneous RF Power Stage Controls and Indicators
REF DES
PANEL
MARKING
DESCRIPTION
A12A1DS1
or
A13A1DS1
MODULE
INSTALLED
When turned on (amber), indicates that RF power module A
or B is installed in the transmitter.
A12A1DS2
or
A13A1DS2
MODULE ON
When turned on (green), indicates that RF power module A
or B is on and is contributing to the transmitter’s RF output.
A12A1DS3
or
A13A1DS3
MODULE FAULT
When turned on (red), indicates that a fault has occurred in
RF power module A or B and it is not contributing to the
transmitter’s RF output.
A12A2DS1
or
A13A2DS1
AC IND
When turned on (amber), indicates the ac input voltage is
being applied to RF power module A or B.
A12A2DS2
or
A13A2DS2
+18V
When turned on (green), indicates the +24 V power supply
voltage is being applied to RF power module A or B and that
the +18 V regulator is functioning.
A12A3F1
or
A13A3F1
+15V
Fuses the +15 V applied from the power module control/
interface PWB to the power amplifier at 1 A.
A12A5DS1
or
A13A5DS1
B+ ON
When turned on (green), indicates that the B+ voltage is
being applied from the switch mode power supply PWB (or
optional battery) to the modulator.
A14E1
through
A14E36
RF Filter
Jumpers
Frequency dependent jumpers that are factory installed for
the customer operating frequency. If a frequency change is
required, change the position of these jumpers (see Figure
MD-16 A or MD-16B).