![Nautel NX300 Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/nautel/nx300/nx300_operation-and-maintenance-manual_3569048124.webp)
NX300 Operations and Maintenance Manual
Operating the transmitter
Page 2-106
Issue 3.0 2012-11-01
Changeover page - changing exciter transfer settings
The
Changeover
page (see
Figure 2.81
), accessed from the
Menu
page, allows control of exciter
auto-changeover.
Figure 2.81: Changeover Page
On this page, set the following exciter information:
•
Active Exciter
- indicates the exciter that is currently active.
•
Main Exciter
- indicates (in green) which exciter is considered to be the primary exciter.
Select
A
or
B
. The default exciter is
A
if the
Standby Exciter
is set to
No
.
NOTE:
Changing
the setting may change the active exciter.
•
Auto Exciter Changeover
-
indicates (in green) if automatic exciter changeover is enabled.
Select
Yes
if automatic changeover is desired or
No
if user selected changeover is desired.
NOTE:
you cannot change the setting if the
Standby Exciter
is set to
No.
•
Standby Exciter
- identifies whether or not a standby exciter is available. This is factory set
and only requires adjustment if an exciter is removed or not functional.
Yes
indicates that a
standby operation is available or desired.
No
indicates that a standby operation is not
available or desired.
Содержание NX300
Страница 2: ......
Страница 4: ......
Страница 8: ...NX300 Operations and Maintenance Manual Page viii Issue 3 0 2012 11 01...
Страница 16: ...NX300 Operations and Maintenance Manual Description Page 1 8 Issue 3 0 2012 11 01 Figure 1 4 Shutback Event...
Страница 18: ...NX300 Operations and Maintenance Manual Description Page 1 10 Issue 3 0 2012 11 01...
Страница 148: ...NX300 Operations and Maintenance Manual Operating the transmitter Page 2 130 Issue 3 0 2012 11 01...
Страница 154: ...NX300 Operations and Maintenance Manual Routine maintenance Page 3 6 Issue 3 0 2012 11 01...
Страница 161: ......