GV5/GV3.5 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 3.2.152
VERSION 0.2 2014-07-23
Capturing Critical Parameters
NOTE
: This feature is available only through the remote AUI.
You can capture critical parameter data for the transmitter’s current state using the AUI’s
Critical
Parameters
). To view this page, select
Critical Parameters
from the
User
Settings
page. From this page, you can select
Capture Meters
(reads all meter values),
Capture
Alarms
(reads all active alarms),
Capture Presets
(reads current preset) and
Capture Settings
(reads
current settings, e.g., active exciter, threshold settings, scale factors, etc.). Once you select the
Capture
button, you can select the associated
Copy
button to copy the data to your remote PC’s clipboard. The
data copies in a tab-delimited format and is ideally suited for pasting into a spreadsheet program.
Select
X
in the upper, right corner to close this page and return to the Home page.
Figure 3.2.130: Critical Parameters page
Содержание GV5
Страница 2: ......
Страница 4: ......
Страница 8: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 2 2014 07 23...
Страница 16: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 8 VERSION 0 2 2014 07 23...
Страница 18: ...VERSION 0 2 2014 07 23 PAGE 3 1 10 LJXUH 9 9 XGLR 3DWK ORFN LDJUDP...
Страница 229: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL OPERATING THE TRANSMITTER PAGE 3 2 212 VERSION 0 2 2014 07 23...
Страница 239: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 10 VERSION 0 2 2014 07 23...
Страница 247: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL NON STANDARD MAINTENANCE PAGE 3 4 8 VERSION 0 2 2014 07 23...
Страница 249: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 2 2014 07 23...
Страница 250: ......