Reject Load or Reject Load/Splitter Interface Assembly
Replacement
as a guide, replace one of the four reject load assemblies or one of the two reject
load/splitter interface assemblies as detailed in this section. Identify the affected reject load, possibly
named in an alarm reference and then replace it, as follows:
RF Drive Splitter A27 - accepts two of the six 5 kW reject power inputs (RF power modules 1-2 and
3-4) (see
“5 kW or 10 kW Reject Load Replacement” on page 4.1.55
)
4-Input Reject Load A29 - accepts four of the six 5 kW reject power inputs (RF power modules 5-6,
7-8, 9-10 and 11-12) (see
“5 kW or 10 kW Reject Load Replacement” on page 4.1.55
)
4-Input Reject Load A31 - accepts the three 10 kW reject power inputs (RF power modules 1-4, 5-8
and 9-12) (see
“5 kW or 10 kW Reject Load Replacement” on page 4.1.55
2-Input Reject Load A13 - accepts the 20 kW reject load power input (RF power modules 1-8) and
the final (30 kW) reject load input (RF power modules 1-12) (see
“Final Reject Load Replacement”
)
Reject Load/Splitter Interface Assembly (A28 and A30) - see
“Reject Load/Splitter Interface Assembly
5 kW or 10 kW Reject Load Replacement
.
NOTE
: 4-input reject load assembly A29 contains four of the six 5 kW reject load circuits. The remaining
two 5 kW reject load circuits are part of 20 kW RF drive splitter assembly A27. 4-input reject load A31
contains the 10 kW reject load circuits.
1.
Open the appropriate front door and remove the appropriate upper, rear panel.
2.
From the front of the transmitter:
Gain access to the suspect reject load [A27 or A29 (5 kW) or A31 (10 kW) by removing the fan
cover (four M5 screws at the top and two hooks in the bottom) and lifting the panel out.
Temporarily remove the reject load/splitter interface assembly (see
Interface Assembly Replacement” on page 4.1.58
Remove the four M4 screws that secure the reject load assembly to the transmitter.
Содержание GV30N
Страница 2: ......
Страница 4: ......
Страница 8: ...GV30N TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 0 1 2014 11 01...
Страница 92: ...GV30N TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 10 VERSION 0 1 2014 11 01...
Страница 318: ...VERSION 0 1 2014 11 01 SD 32 Figure SD 32 NAE107A or NAE107A 01 Exciter...
Страница 327: ...VERSION 0 1 2014 11 01 SD 41 Figure SD 41 NAFP109B Output Power Probe and Sample PWBs...
Страница 333: ...VERSION 0 1 2014 11 01 SD 47 Figure SD 47 UPS Interface Assembly Optional Nautel Part 219 5179 UPS Interface Upgrade Kit...
Страница 337: ...GV30N TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 0 1 2014 11 01...
Страница 351: ...VERSION 0 1 2014 11 01 MD 14 Figure MD 14 NAPA31C Power Amplifier PWB Q1...
Страница 354: ...VERSION 0 1 2014 11 01 MD 17 Figure MD 17 NAI23A RF Drive Splitter Changeover Assembly FRONT BACK...
Страница 356: ...VERSION 0 1 2014 11 01 MD 19 Figure MD 19 NAL16 2 Input Reject Load Assembly TOP VIEW END VIEW 2 INPUT REJECT PWB A1...
Страница 363: ...GV30N TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 0 1 2014 11 01...
Страница 364: ......