![Nautel GV30N Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/nautel/gv30n/gv30n_troubleshooting-manual_3516644033.webp)
GV30N TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 0.1 2014-11-01
PAGE 4.1.25
Module #: PS A (or B)
AC Fail
Power Supply (red)
This alarm occurs if one of the two module power supplies (1 or 2) is
reporting an ac failure, indicating its ac input voltage is less than 175 V ac.
If a bank of power supply modules are indicating an AC Fail alarm, it is
possible that an ac phase loss has occurred. Check the ac voltage applied to
the suspect power supply module. If the ac voltage is acceptable, replace
the module (see
“Power Supply Module Replacement” on
).
Module #: PS A (or B)
Current Limit
Power Supply (red)
This alarm occurs if one of the two module power supplies (1 or 2) is
reporting a current limit, indicating that the power being delivered by the
module has reached 2750 W. This may relate to the operating mode and/or
the load impedance at the transmitter’s RF output. Check for other
transmitter related alarms.
Module #: PS A (or B)
Fail
Power Supply (red)
This alarm occurs if one of the two module power supplies (1 or 2) is
reporting a PS failure, indicating its output voltage is outside its acceptable
range, based on the control setting. Check the dc voltage output of the
suspect power supply module. If the dc voltage is out of tolerance, replace
the power supply module (see
“Power Supply Module Replacement”
). If the voltage is acceptable, suspect the PS interface
PWB (A1).
Module #: PS A (or B)
High Temperature [PS
A (or B) Temp]
Power Supply (red)
This alarm occurs if one of the two module power supplies (1 or 2) is
reporting a high temperature alarm, indicating its operating temperature
has exceeded its internal threshold of 105°C (221°F). Both module power
supplies are inhibited while this fault exists. This alarm is most likely caused
by a module fan failure or blockage. Verify the module turns on and its fan
is operational. If the fan is not operational, inspect it for possible blockage.
If necessary, replace the power supply module (see
Module Replacement” on page 4.1.49
). If the alarm persist after
replacing the module, suspect the PS interface PWB (A1).
Module #: PS A (or B)
Low Line
Power Supply (red)
This alarm occurs if one of the two module power supplies (1 or 2) is
reporting a low ac input voltage (less than 175 V ac, higher than 90 V ac).
The power supply will limit its associated module’s output.
Module #: PS A (or B)
Missing
Power Supply (red)
This alarm occurs if the module power supply (A or B) is removed, or has not
been detected on the serial bus. Install an operational power supply
module. The alarm may persist for several seconds after replacing a power
supply module, before the power supply module is recognized. If the alarm
persists after one minute, try reseating the power supply module. This alarm
may also be caused by an ac power loss to the power supply module.
Device and
Alarm Name
(AUI, UI)
Controller Front
Panel LED (color)
Description and Troubleshooting Action
Содержание GV30N
Страница 2: ......
Страница 4: ......
Страница 8: ...GV30N TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 0 1 2014 11 01...
Страница 92: ...GV30N TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 10 VERSION 0 1 2014 11 01...
Страница 318: ...VERSION 0 1 2014 11 01 SD 32 Figure SD 32 NAE107A or NAE107A 01 Exciter...
Страница 327: ...VERSION 0 1 2014 11 01 SD 41 Figure SD 41 NAFP109B Output Power Probe and Sample PWBs...
Страница 333: ...VERSION 0 1 2014 11 01 SD 47 Figure SD 47 UPS Interface Assembly Optional Nautel Part 219 5179 UPS Interface Upgrade Kit...
Страница 337: ...GV30N TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 0 1 2014 11 01...
Страница 351: ...VERSION 0 1 2014 11 01 MD 14 Figure MD 14 NAPA31C Power Amplifier PWB Q1...
Страница 354: ...VERSION 0 1 2014 11 01 MD 17 Figure MD 17 NAI23A RF Drive Splitter Changeover Assembly FRONT BACK...
Страница 356: ...VERSION 0 1 2014 11 01 MD 19 Figure MD 19 NAL16 2 Input Reject Load Assembly TOP VIEW END VIEW 2 INPUT REJECT PWB A1...
Страница 363: ...GV30N TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 0 1 2014 11 01...
Страница 364: ......