![Nautel GV30N Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/nautel/gv30n/gv30n_troubleshooting-manual_3516644035.webp)
GV30N TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 0.1 2014-11-01
PAGE 4.1.27
Rack #: High Ambient
Temperature (High
Amb Temp)
-
This alarm is indication only and occurs if the transmitter’s ambient
temperature exceeds 60°C (140°F). Check the intake air filters or cooling
system.
Rack #: LVPS A (or B)
Fail
Power Supply (red)
This alarm occurs if LVPS module A (U2) or B (U3) is reporting a PS failure,
indicating its output voltage is outside its acceptable range, based on the
control setting. Check the dc output voltage of the suspect LVPS. If the dc
voltage is out of tolerance, replace the LVPS module (see
). If the dc voltage is acceptable, suspect
the PS interface PWB (A1).
Rack #: LVPS A (or B)
AC Fail
Power Supply (red)
This alarm occurs if LVPS module A (U2) or B (U3) is reporting an ac failure,
indicating its ac input voltage is less than 175 V ac. Check the ac voltage
applied to the suspect LVPS module. If the ac voltage is acceptable, replace
the LVPS module (see
“LVPS Module Replacement” on page 4.1.47
).
Rack #: LVPS A (or B)
High Temperature
[LVPS A (or B) Temp]
Power Supply (red)
This alarm occurs if LVPS module A (U2) or B (U3) is reporting a high
temperature alarm, indicating its operating temperature has exceeded its
internal threshold of 105°C (221°F). This alarm is most likely caused by a
module fan failure or blockage. Allow the module to cool and attempt to
reset the alarm. Verify the module turns on and its fan is operational. If the
fan is not operational, inspect it for possible blockage. If necessary, replace
the LVPS module (see
“LVPS Module Replacement” on page 4.1.47
).
Rack #: LVPS A (or B)
Low Line
Power Supply (red)
This alarm occurs if LVPS A (U2) or LVPS B (U3) is reporting a low ac input
voltage (less than 175 V ac, higher than 90 V ac). The power supply will
limit its associated module’s output.
.
Rack #: LVPS A (or B)
Missing
Power Supply (amber) This alarm occurs if LVPS module A (U2) or B (U3) has been removed. Install
an operational LVPS module. The alarm may persist for several seconds after
replacing an LVPS module, before the LVPS module is recognized. If the
alarm persists after one minute, try reseating the LVPS module. This alarm
may also be caused by an ac power loss to the LVPS module. This alarm only
occurs if the system is configured to use LVPS A or B, as applicable (see
“Configuring LVPS Hardware” on page 3.2.114
) of the Operations &
Maintenance Manual.
Rack #: Module
Extraction Shutback
Power Amplifier (red) This alarm occurs if the RF power module is removed without first being
inhibited via its front panel switch. Try reseating the RF power module. If
the alarm persists, suspect a fault with circuitry on the associated module
control/interface PWB.
Rack #: Reject Fan
Volts Fail (Rej Fan V
Fail)
Power Supply (red)
This alarm occurs if the fan voltage for the module is 10% high or 10% low
from the expected value. This may be the result of a fault with the
associated circuit on the module control/interface PWB (A3).
Device and
Alarm Name
(AUI, UI)
Controller Front
Panel LED (color)
Description and Troubleshooting Action
Содержание GV30N
Страница 2: ......
Страница 4: ......
Страница 8: ...GV30N TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 0 1 2014 11 01...
Страница 92: ...GV30N TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 10 VERSION 0 1 2014 11 01...
Страница 318: ...VERSION 0 1 2014 11 01 SD 32 Figure SD 32 NAE107A or NAE107A 01 Exciter...
Страница 327: ...VERSION 0 1 2014 11 01 SD 41 Figure SD 41 NAFP109B Output Power Probe and Sample PWBs...
Страница 333: ...VERSION 0 1 2014 11 01 SD 47 Figure SD 47 UPS Interface Assembly Optional Nautel Part 219 5179 UPS Interface Upgrade Kit...
Страница 337: ...GV30N TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 0 1 2014 11 01...
Страница 351: ...VERSION 0 1 2014 11 01 MD 14 Figure MD 14 NAPA31C Power Amplifier PWB Q1...
Страница 354: ...VERSION 0 1 2014 11 01 MD 17 Figure MD 17 NAI23A RF Drive Splitter Changeover Assembly FRONT BACK...
Страница 356: ...VERSION 0 1 2014 11 01 MD 19 Figure MD 19 NAL16 2 Input Reject Load Assembly TOP VIEW END VIEW 2 INPUT REJECT PWB A1...
Страница 363: ...GV30N TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 0 1 2014 11 01...
Страница 364: ......