GV30N TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 0.1 2014-11-01
PAGE 4.1.17
Controller: Turn On
Delay (Delaying Turn
On)
Exciter (red)
This alarm occurs, if the turn-on delay function is enabled, and transmitter is
not permitted turn-on until the delay period elapses. The turn-on delay
function is enabled upon an ac power failure and is typically used to add
delay for use with an external generator.
Controller: Very Low
Forward Power (Very
Low Fwd Power)
Output Network
(amber)
This alarm occurs if transmitter’s average forward power is below the low
forward power threshold (defaulted to 12.5% of the setpoint and is user
adjustable). Check for associated alarms, and follow the associated
troubleshooting procedure, if present.
Controller: +1.2V Fail Power Supply (red)
This alarm occurs if the +1.2 V supply in the controller is 10% higher or
10% lower than its desired value. Check the output voltage of the LVPS
module. If necessary, replace the LVPS (see
). There may also be a problem with the
controller’s power supply PWB.
Controller: +1.8V Fail Power Supply (red)
This alarm occurs if the +1.8 V supply in the controller is 10% higher or
10% lower than its desired value. Check the output voltage of the LVPS
module. If necessary, replace the LVPS (see
). There may also be a problem with the
controller’s power supply PWB.
Controller: +3.3V Fail Power Supply (red)
This alarm occurs if the +1.2 V supply in the controller is 10% higher or
10% lower than its desired value. Check the output voltage of the LVPS
module. If necessary, replace the LVPS (see
). There may also be a problem with the
controller’s power supply PWB.
Controller: 10kW
Reject Fan 1 - 3 Fail
(10kW Rej Fan1-3
Fail)
Output Network
(red)
This alarm occurs if the 10 kW reject load () cooling fans are enabled and
the speed of a cooling fan [B6 (1), B7 (2) or B8 (3] is below 2000 RPM. 10
kW reject load cooling fans are enabled only when the reject load power is
greater than 300 W, possibly due to an RF power module removal or failure
or power supply removal or failure. Inspect the fan and, if necessary, replace
it (see
“Cooling Fan Replacement” on page 4.1.53
Controller: +12V A
Fail
Power Supply (red)
This alarm occurs if the +12 V supply in the controller is 10% lower or 10%
higher than the desired value. Check the output voltage of the LVPS module.
If necessary, replace the LVPS (see
). There may also be a problem with the controller’s power
supply PWB.
Device and
Alarm Name
(AUI, UI)
Controller Front
Panel LED (color)
Description and Troubleshooting Action
Содержание GV30N
Страница 2: ......
Страница 4: ......
Страница 8: ...GV30N TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 0 1 2014 11 01...
Страница 92: ...GV30N TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 10 VERSION 0 1 2014 11 01...
Страница 318: ...VERSION 0 1 2014 11 01 SD 32 Figure SD 32 NAE107A or NAE107A 01 Exciter...
Страница 327: ...VERSION 0 1 2014 11 01 SD 41 Figure SD 41 NAFP109B Output Power Probe and Sample PWBs...
Страница 333: ...VERSION 0 1 2014 11 01 SD 47 Figure SD 47 UPS Interface Assembly Optional Nautel Part 219 5179 UPS Interface Upgrade Kit...
Страница 337: ...GV30N TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 0 1 2014 11 01...
Страница 351: ...VERSION 0 1 2014 11 01 MD 14 Figure MD 14 NAPA31C Power Amplifier PWB Q1...
Страница 354: ...VERSION 0 1 2014 11 01 MD 17 Figure MD 17 NAI23A RF Drive Splitter Changeover Assembly FRONT BACK...
Страница 356: ...VERSION 0 1 2014 11 01 MD 19 Figure MD 19 NAL16 2 Input Reject Load Assembly TOP VIEW END VIEW 2 INPUT REJECT PWB A1...
Страница 363: ...GV30N TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 0 1 2014 11 01...
Страница 364: ......