![Nautel GV30N Скачать руководство пользователя страница 295](http://html1.mh-extra.com/html/nautel/gv30n/gv30n_troubleshooting-manual_3516644295.webp)
VERSION 0.1 2014-11-01
SD-9
Figure SD-9: GV30N Transmitter - RF Power Stage (Sheet 2 of 3)
-90°
0°
-90°
-180°
8
7
A5P1
A5P1
A5P1
A5P1
J22
GND
GND
GND
GND
GND
GND
J1
L8
L5
J2
5-8
W
W
W
W
B
B
B
B
B9L1
B8L1
B7L1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
PART OF
A30
N/A
6
J24
J23
+5V
J1
J1
J1
L7
L6
J4
J3
J1
N/C
LOAD
ASSY
A31
LOAD
A29
ASSY
W
W
B
B
N/A
B6L1
GND
N/A
N/A
GND
N/A
ASSY
*
PA VOLTS (8B) +
PA VOLTS (8A) -
PA VOLTS (7B) +
PA VOLTS (7A) -
PA VOLTS (7B) -
PA VOLTS (7A) +
PA VOLTS (6B) -
PA VOLTS (6A) +
PA VOLTS (5B) -
PA VOLTS (5B) +
PA VOLTS (5A) -
J22
**
E2
E22
E7
67
68
FAN TACH 5
FAN TACH 6
65
FAN TACH 3
J21
62
63
FAN TACH 1
GND
60
13
17
A5P1
A5P1
A5P1
**
71
72
69
15
16
12
9
10
RF DRIVE
7
J21
3
BIAS 3
5
BIAS 4
1
BIAS 1
PA V 4
THRU
38
PA V 3
THRU
29
39
PA V 2
THRU
PA V 1
28
THRU
A5P1
8
A23
7
A22
PART OF
A20
NOTES:
A24
SHEET 3
FROM RF
SHEET 1
FROM RF
POWER STAGE
SHEET 3
SHEET 2
MONITOR STAGE
A1J1/
REJECT
A1J1/
REJECT
B11L1
5kW REJ FAN 5
R
R
5kW REJ FAN 3
10kW REJ FAN 3
R
R
10kW REJ FAN 1
A1J4
3
P15
1
9
A1J2
4
3
6
1
W68P2
2
1
A2J6
B11P1
2
1
A2J4
B9P1
3
1
A2J3
3
B8P1
2
B7P1
A2J1
2
3
10
8
7
A1J6
5
3
2
A31W1P1
10
8
7
A1J1
5
3
2
A29W1P1
18
12
11
P15
6
7
A1J3
5
3
2
W67P1
SHEET 3
*
*
PA VOLTS (8B) -
PA VOLTS (8A) +
PA VOLTS (6B) +
PA VOLTS (6A) -
PA VOLTS (5A) +
RF DRIVE (8)
RF DRIVE (7)
RF DRIVE (6)
RF DRIVE (5)
*
J24
J23
**
**
E4
E23
E1
E21
E8
E3
E20
E9
J12
W46P2
J11
W47P2
66
FAN TACH 4
J14
W44P2
J13
W45P2
64
18
61
4
FAN TACH 2
**
**
59
70
14
11
RF DRIVE
6
BIAS 2
8
2
49
48
58
19
PART OF
6
A21
PART OF
MODULE 5
PART OF
RF POWER
J7
W50P1
J5
W48P1
J6
W49P1
POWER STAGE
POWER STAGE
FROM RF
FROM CONTROL/
A1J2
J4
4-INPUT
A1J2
4-INPUT
R
-
+
B11
5kW REJ FAN 4
B10L1
-
+
B9
R
-
+
B8
10kW REJ FAN 2
-
+
B7
4
2
5
8
7
2
3
1
B10P1
A2J5
3
2
2
1
A2J2
1
3
9
6
4
B6P1
1
9
6
4
1
A1J4
19
13
N/C
10
9
8
4
1
E10
-
+
B10
-
+
B6
(SAME AS A20)
(SAME AS A20)
A23
(SAME AS A20)
(SAME AS A20)
A22
RF POWER
RF POWER
(SAME AS A20)
(SAME AS A20)
RF POWER
RF POWER
PART OF
POWER STAGE
SHEET 2
INTERFACE
PWB
A18
FAN VOLTS -
FAN VOLTS -
FAN VOLTS +
# FAULT -
# POWER -
RF DRIVE
STAGE
# MODULE INHIBIT -
REJ PWR SAMPLE
HEATSINK TEMP +
A20
2) RF POWER MODULE OUTPUT CONNECTOR J1 AND SPECIFIC 10kW
COMBINER/FILTER ASSY CONNECTOR ARE BLIND-MATE CONNECTIONS.
CONNECTOR P1 AND MODULE CONTROL/INTERFACE PWB CONNECTOR
1) RF POWER MODULE/SPLITTER INTERFACE PWB (A5) EDGE CARD
ARE BLIND-MATE CONNECTIONS.
SEE RF POWER MODULE 1 FOR PIN INFORMATION.
** DENOTES THAT CONNECTOR SYMBOL REPRESENTS MULTIPLE PINS.
* DENOTES GROUND CONNECTION BETWEEN RF POWER MODULE AND
TRANSMITTER CHASSIS IS BLIND MATE.
10kW REJ LD FAN VOLTS -
10kW REJ LD FAN VOLTS +
5kW & 10kW REJ LD FAN VOLTS -
5kW & 10kW REJ LD FAN VOLTS -
5kW & 10kW REJ LD FAN VOLTS -
5kW & 10kW REJ LD FAN VOLTS +
5kW & 10kW REJ LD FAN VOLTS +
FAN TACH
FAN VOLTS -
FAN VOLTS -
FAN VOLTS +
FAN TACH
FAN VOLTS +
FAN TACH
FAN VOLTS -
FAN VOLTS +
FAN VOLTS -
FAN TACH
FAN VOLTS -
FAN VOLTS +
10
8
7
5
3
2
10kW REJ LD PWR 9-12 SAMPLE
10kW REJ LD PWR 5-8 SAMPLE
SPLITTER
INTERFACE
A31W1P2/P3
10
8
7
5
3
2
5kW REJ LD PWR 7-8 SAMPLE
5kW REJ LD PWR 9-10 SAMPLE
A29W1P2/P3
10kW COMBINER/FILTER
OUTPUT 5-8
SHEET 2
TO CONTROL/
TO RF POWER STAGE
S2190306 V1
MODULE
PART OF
MODULE
RF POWER
MODULE
MODULE
RF POWER
A21
PART OF
MODULE
MODULE
FROM AC/DC
(RACK 2)
CONTROL/
PART OF
MODULE
FAN VOLTS +
FROM
HEATSINK TEMP -
# MODULE PRESENT -
RF DRIVE SAMPLE
MODULE 5
PART OF
RF POWER
FILTER ASSY
10kW COMBINER/
10kW REJ LD PWR (9-12)
10kW REJ LD PWR (5-8)
J3
W66P2
J2
W50P2
10kW REJ LD PWR (1-4)
5kW REJ LD PWR (9-10)
5kW REJ LD PWR (11-12)
J4
W65P2
J3
W64P2
J1
W18P2
5kW REJ LD PWR (7-8)
5kW REJ LD PWR (5-6)
J1
W48P2
J2
W49P2
10kW REJ LD FAN VOLTS +
10kW REJ LD FAN VOLTS -
5kW & 10kW REJ LD FAN VOLTS -
5kW & 10kW REJ LD FAN VOLTS +
5kW & 10kW REJ LD FAN VOLTS +
FAN VOLTS +
FAN TACH
FAN VOLTS -
FAN TACH
FAN VOLTS +
9
6
4
1
9
6
REJECT LOAD/
10kW REJ LD PWR 1-4 SAMPLE
4
1
5kW REJ LD PWR 5-6 SAMPLE
5kW REJ LD PWR 11-12 SAMPLE
MONITOR STAGE
10kW REJ FAN 3 TACH
10kW REJ LD PWR 9-12 SAMPLE
10kW REJ LD PWR 5-8 SAMPLE
5kW REJ FAN 4 TACH
5kW REJ FAN 5 TACH
5kW REJ LD PWR 7-8 SAMPLE
5kW REJ LD PWR 9-10 SAMPLE
10kW REJ FAN 2 TACH
10kW REJ FAN 1 TACH
10kW REJ LD PWR 1-4 SAMPLE
5kW REJ LD PWR 11-12 SAMPLE
5kW REJ FAN 3 TACH
5kW REJ LD PWR 5-6 SAMPLE
Содержание GV30N
Страница 2: ......
Страница 4: ......
Страница 8: ...GV30N TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 0 1 2014 11 01...
Страница 92: ...GV30N TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 10 VERSION 0 1 2014 11 01...
Страница 318: ...VERSION 0 1 2014 11 01 SD 32 Figure SD 32 NAE107A or NAE107A 01 Exciter...
Страница 327: ...VERSION 0 1 2014 11 01 SD 41 Figure SD 41 NAFP109B Output Power Probe and Sample PWBs...
Страница 333: ...VERSION 0 1 2014 11 01 SD 47 Figure SD 47 UPS Interface Assembly Optional Nautel Part 219 5179 UPS Interface Upgrade Kit...
Страница 337: ...GV30N TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 0 1 2014 11 01...
Страница 351: ...VERSION 0 1 2014 11 01 MD 14 Figure MD 14 NAPA31C Power Amplifier PWB Q1...
Страница 354: ...VERSION 0 1 2014 11 01 MD 17 Figure MD 17 NAI23A RF Drive Splitter Changeover Assembly FRONT BACK...
Страница 356: ...VERSION 0 1 2014 11 01 MD 19 Figure MD 19 NAL16 2 Input Reject Load Assembly TOP VIEW END VIEW 2 INPUT REJECT PWB A1...
Страница 363: ...GV30N TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 0 1 2014 11 01...
Страница 364: ......