temperature is detected in them.

Protects the water heater or the solar collector of freezing.

Protects the solar collector of overheating. If the hot water in the water heater is not going to 
be used for a long time, the Holiday mode might be activated, which automatically takes the 
heat off from the water heater during the night, so it can be warmed up again on the next day 
and takes the heat off from the solar collector.

Information about the condition of the anode protector.

Information   if   a   leakage   from   the   heater   to   a   hull   higher   than   30mA   occurs   and 
automatically turning off the water heater when such a leakage is registered.

Uses self adapting and energy saving algorithm for heating up the water with the electrical 
heater.

Diagnostics of all used circuits. 

Two timers which allows you to set up the work time of the electrical heater. This might be 
used, for instance, for automatic work only in the time interval with cheaper electricity rates 
or to set up a time when the water heater starts being electrically heated up if the sun wasn't 
strong enough by this time.

System time and date. Knowing what time it is while you are in the bathroom is really 
convenient.

Measures the consumed electricity in kWh and shows it in a digital view for two rates or in a 
graphic view hour by hour for the whole day.

Shows at the same time the temperature of the water in the upper and the bottom  section of 
the   water   heater,   the   temperature   in   the   heat   exchanger   of   the   solar   collector   and   the 
temperature of the water in the boiler.

Monitors the condition of the heater and shows a message if the water is not heated up for 
the presumed time. 

Connection scheme of NHC-H41-2 with a water heater

NHC-H41-2 Reference Manual ver 2.2

page  2 / 15

Содержание NHC-H41

Страница 1: ...perature regulators in a joint controller the advantages of the different heat sources are appropriately combined For example if the sun wasn t strong enough during the day you can always set up the c...

Страница 2: ...Two timers which allows you to set up the work time of the electrical heater This might be used for instance for automatic work only in the time interval with cheaper electricity rates or to set up a...

Страница 3: ...f its work modes Automatic mode with electrical water heating Mode with electrical water heating in a restricted part of the day Combined mode 1 2 3 Solar mode Boiler mode Holiday mode for automatic p...

Страница 4: ...stricted by a timer On this mode the water is heated up both by the electrical heater of the water heater and by the serpentine which is connected to the solar collector installation as the heater can...

Страница 5: ...energy and the energy from the additional heat source is not enough and need to be used the electrical heater For instance if you need hot water in the night when there is no sun and the heating boil...

Страница 6: ...ovide the required amounts of hot water Holiday mode If you are not using hot water for a long time for instance if you are on vacation business trip etc and during this season the sun is strong enoug...

Страница 7: ...me of the set work parameters of the system All possible data is displayed successively by pressing the View Enter button It appears in the following order Set temperature Temperature of the water hea...

Страница 8: ...he temperature sensor in the bottom section of the water heater It is on short circuit S1 Frost On turning on the power the water in the water heater has a negative temperature and it is possible to b...

Страница 9: ...conds or until a button is pressed then the screen goes back to its initial state Important If the consumed daily or night electricity is displayed in the field Measured or set parameters pressing and...

Страница 10: ...he registered problem can be found in the Measured or set parameters field Design III Settings The screen has a similar look for all the settings of the work parameters On the picture is the setting o...

Страница 11: ...atic mode with electrical heating up the water and the display changes according to this mode By pressing again the Mode Set button the work mode of the water heater changes and the display changes to...

Страница 12: ...off or which mode is currently activated the temperature regulator constantly monitors the temperature both of the water in the tank and of the solar collector and if it is necessary activates safety...

Страница 13: ...off For a temperature difference between the collector and the water heater more than Pump On the pump will turn on and will work until the difference gets less than Pump Off 7 Setting the differenti...

Страница 14: ...y network occurs no electricity For the battery not to run down if the water heater is off for a long time when there is no power supply for more than 18 hours the clock stops and on the next turning...

Страница 15: ...ial settings use the following instructions the field which is going to be changed is blinking process to the next field of the same parameter by pressing button and the new field starts blinking incr...

Отзывы: