Setting the temperature

When  the   water  heater  is  on,  by pressing  any  of  the  buttons   “

”  or  “

”,   the  mode 

Changing   the   set   temperature

  activates.   Further   pressing   the   same   buttons   changes   the 

temperature setting. By pressing the  

View/Enter

 button, the new setting is saved and the display 

goes back to its previous state. If no button has been pressed for 5 seconds, the display goes back to 
its previous state, but the changes won't be saved. If one of the buttons “

” or “

” is pressed and 

held for more than 0.8 seconds, the value of the temperature automatically increases or decreases 
with 3 digits per second. Pressing  “

” and “

” at the same time and holding them for more than 

0.8 sec. turns on the ECO mode and returns the main screen. The ECO mode can be activated 
directly by pressing both buttons while on main screen (without entering the setting Changing the 
set temperature). The temperature can be adjusted from 20 to 75°С.

Safety modes

No matter whether the water heater is on or off, or which mode is currently activated, the 

temperature regulator constantly monitors the temperature both of the water in the tank and of the 
solar collector, and if it is necessary activates safety mode to protect the tank or the collector of 
freezing or safety mode to protect the collector of overheating. Therefore, if there is a forecast for 
low temperatures or a chance for the collector to get overheated, it is recommended not to turn off 
the power of the water heater!

Setting mode 

Most of the water heater's predefined parameters could be adjusted. Entering Setting mode is 

available from 

Design II

  of the screen, when the water heater is on, by pressing and holding for 

more than 1.5 seconds the 

Mode/Set

 button. Exception of the rule for the water heater to be on, is 

the setting of the time and date, when they are blinking, i.e. they haven't been set yet. In this case 
this setting could be done even if the water heater is off. By entering the Setting mode, the screen 
goes to 

Design III

. Pressing 

Mode/Set

 button forwards to the next setting screen. The order of the 

settings is the following:

1

Setting time

NHC-H41-2 Reference Manual ver 2.2

page  12 / 15

Содержание NHC-H41

Страница 1: ...perature regulators in a joint controller the advantages of the different heat sources are appropriately combined For example if the sun wasn t strong enough during the day you can always set up the c...

Страница 2: ...Two timers which allows you to set up the work time of the electrical heater This might be used for instance for automatic work only in the time interval with cheaper electricity rates or to set up a...

Страница 3: ...f its work modes Automatic mode with electrical water heating Mode with electrical water heating in a restricted part of the day Combined mode 1 2 3 Solar mode Boiler mode Holiday mode for automatic p...

Страница 4: ...stricted by a timer On this mode the water is heated up both by the electrical heater of the water heater and by the serpentine which is connected to the solar collector installation as the heater can...

Страница 5: ...energy and the energy from the additional heat source is not enough and need to be used the electrical heater For instance if you need hot water in the night when there is no sun and the heating boil...

Страница 6: ...ovide the required amounts of hot water Holiday mode If you are not using hot water for a long time for instance if you are on vacation business trip etc and during this season the sun is strong enoug...

Страница 7: ...me of the set work parameters of the system All possible data is displayed successively by pressing the View Enter button It appears in the following order Set temperature Temperature of the water hea...

Страница 8: ...he temperature sensor in the bottom section of the water heater It is on short circuit S1 Frost On turning on the power the water in the water heater has a negative temperature and it is possible to b...

Страница 9: ...conds or until a button is pressed then the screen goes back to its initial state Important If the consumed daily or night electricity is displayed in the field Measured or set parameters pressing and...

Страница 10: ...he registered problem can be found in the Measured or set parameters field Design III Settings The screen has a similar look for all the settings of the work parameters On the picture is the setting o...

Страница 11: ...atic mode with electrical heating up the water and the display changes according to this mode By pressing again the Mode Set button the work mode of the water heater changes and the display changes to...

Страница 12: ...off or which mode is currently activated the temperature regulator constantly monitors the temperature both of the water in the tank and of the solar collector and if it is necessary activates safety...

Страница 13: ...off For a temperature difference between the collector and the water heater more than Pump On the pump will turn on and will work until the difference gets less than Pump Off 7 Setting the differenti...

Страница 14: ...y network occurs no electricity For the battery not to run down if the water heater is off for a long time when there is no power supply for more than 18 hours the clock stops and on the next turning...

Страница 15: ...ial settings use the following instructions the field which is going to be changed is blinking process to the next field of the same parameter by pressing button and the new field starts blinking incr...

Отзывы: