background image

VIII

Operation Instruction

3

.

Two pipe or four pipe for choice.

 

4

.

3

 

F

an

 

s

peed

+

a

uto,

 

timer

 

s

witch

 

f

or

 

d

aily

 

o

r

 

w

eek

  .

5 With

 

daily

 

p

rogrammable

 

f

unction

4

 

p

eriod

 

s

ettings

.

  6

.

S

electable

 

80mmx80mm hidden box.

Accuracy

Sensing Element

Power Consumption

Power Supply

Current Load

 

External Material

Dimension
Ambient Temp.
Storage Temp.

±

1

NTC

 

<0.5W 

AC85~260V, 50/60HZ

3A

PC+ABS (flame retardant

86x86x13.3mm

 0-45

℃,

5-95

RH(Non

-

condensing

-5~55

Set Temp. Range

10

℃ - 

40

I. Product Summary:

II. Technical Parameter:

IV. User Interface Explanation

 

 2

.

Blue

 

or

 

w

hite

 

b

ack

 

l

ight

 

f

or

 

c

ustomer

 

c

hoose

.

TOL43-AC Series  thermostats are designed to control the fans and valves 
in air conditioner applications via comparison of the room temperature and
setting temperature as reaching the aim of comfort and saving energy. 

Installation Box

 

80x80mm

V. Model Definition

AC 2: Two pipe, for air conditioning 

AC 4: Four pipe, for air conditioning

1. Setting Power on/off

Press     to turn on/off the power.

2. Setting Temperature

Press        to set the temperature.

3. Setting the System Mode

Then go into day programmable setting.  

Press 

, 1 (for example) will flash in the position of 1234567.

4. Setting the Fan Speed

Press       to select the fan speed.

In auto mode, the fan will run according to the comparison of room
temperature and set temperature.

Press 

 , mm will flash in the position of hh: mm.

Press         to adjust the minute.

5. Setting the Day Program Schedules.

Press         to adjust the hour.
Press 

M

  , period 1        and mm will flash.

Press         to adjust the minute.
Press         to confirm the setting;
Press  

M

 , period 2        and hh will flash.

 

7

.

Precise comfort control keeps temperature within1°C of the level you set.

1.Square LCD display, more clear to see.

 

TOL43-AC LCD SCREEN THERMOSTAT

VII.Wiring Digram

III. Main Functions and Characteristics

For example: TOL43-AC2

VI. Model Spec

TOL43-AC2

TOL43-AC4

Spec

2 Pipe

4 Pipe

Factory default is 26 

.

Press  

M

  to select       heating,      cooling or        ventilation. 

Factory Default is ventilation.

is Low speed(Factory default);
is Mid speed;

is High speed;

is Auto speed.

Press and hold  

M  

for 3 sec., hh will flash in the position of hh: mm.

Press        to adjust the hour.

The above is the steps to set real time.

Press         to adjust the week.
Press 

M

 , period 1       and hh will flash.

Press         to adjust the hour.
Press  

M

  , period 2        and mm will flash.

Press        to adjust the minute.
Press       to confirm the setting;
Press 

 M 

 , period 3        and hh will flash.

Press         to adjust the hour.
Press 

M

  , period 3       and mm will flash.

Press         to adjust the minute.
Press      to confirm the setting;
Press 

M

  , period 4      and hh will flash.

Press        to adjust the hour.
Press 

M

 , period 4        and mm will flash.

Press       to adjust the minute.
Press       to confirm the setting;
Press 

M

  , loop  will display in the screen.

One day programmable setting is finished.

Fan Speed

3 Fan speed+Auto

3 Fan speed+Auto

Daily 
Programmable

Timer Switch

Отзывы: