background image

TABLE 19. Bluetooth Low Power Modes

Command

Event

Description

Set Default Link Policy

Set Default Link Policy Confirm

Defines the link policy used for any incoming or outgoing link

Get Default Link Policy

Get Default Link Policy Confirm

Returns the stored default link policy

Set Link Policy

Set Link Policy Confirm

Defines the modes allowed for a specific link

Get Link Policy

Get Link Policy Confirm

Returns the actual link policy for the link

Enter Sniff Mode

Enter Sniff Mode Confirm

 

Exit Sniff Mode

Exit Sniff Mode Confirm

 

Enter Hold Mode

Enter Hold Mode Confirm

 

 

Power Save Mode Changed

Remote device changed power save mode on the link

TABLE 20. Audio Control Commands

Command

Event

Description

Establish SCO Link

Establish SCO Link Confirm

Establish SCO Link on existing RFComm Link

 

SCO Link Established Indicator

A remote device has established a SCO link to the local
device

Release SCO Link

Release SCO Link Confirm

Release SCO Link Audio Control

 

SCO Link Released Indicator

SCO Link has been released

Change SCO Packet Type

Change SCO Packet Type Confirm

Changes Packet Type for existing SCO link

 

SCO Packet Type changed indicator

SCO Packet Type has been changed

Set Audio Settings

Set Audio Settings Confirm

Set Audio Settings for existing Link

Get Audio Settings

Get Audio Settings Confirm

Get Audio Settings for existing Link

Set Volume

Set Volume Confirm

Configure the volume

Get Volume

Get Volume Confirm

Get current volume setting

Mute

Mute Confirm

Mutes the microphone input

TABLE 21. Wake Up Functionality

Command

Event

Description

Disable Transport Layer

Transport Layer Enabled

Disabling the UART Transport Layer and activates the
Hardware Wakeup function

TABLE 22. SPP Port Configuration and Status

Command

Event

Description

Set Port Config

Set Port Config Confirm

Set port setting for the virtual serial port link over the air

Get Port Config

Get Port Config Confirm

Read the actual port settings for a virtual serial port

Port Config Changed

Notification if port settings were changed from remote device

SPP Get Port Status

SPP Get Port Status Confirm

Returns status of DTR, RTS (for the active RFComm link)

SPP Port Set DTR

SPP Port Set DTR Confirm

Sets the DTR bit on the specified link

SPP Port Set RTS

SPP Port Set RTS Confirm

Sets the RTS bit on the specified link

SPP Port BREAK

SPP Port BREAK

Indicates that the host has detected a break

SPP Port Overrun Error

SPP Port Overrun Error Confirm

Used to indicate that the host has detected an overrun error

SPP Port Parity Error

SPP Port Parity Error Confirm

Host has detected a parity error

SPP Port Framing Error

SPP Port Framing Error Confirm

Host has detected a framing error

 

SPP Port Status Changed

Indicates that remote device has changed one of the port
status bits

www.national.com

20

LMX9838

Содержание LMX9838

Страница 1: ... firmware features point to point and point to multipoint link management supporting data rates up to the theoretical maximum over RFComm of 704 kbps The internal memory supports up to 7 active Bluetooth data links and one active SCO link The on chip Patch RAM provided for lowest cost and risk al lows the flexibility of firmware upgrade The module is lead free and RoHS Restriction of Hazardous Sub...

Страница 2: ...tion Profile SYNC Headset HSP Handsfree Profile HFP Basic Imaging Profile BIP Basic Printing Profile BPP On chip application including Default connections Command Interface Link setup and configuration also Multipoint Configuration of the module Service database modifications UART Transparent mode Optimized cable replacement Automatic transparent mode Event filter 5 3 COMPLIANCE FCC compliance The...

Страница 3: ...ault Layout Description RXD 12 I Host Serial Port Receive Data TXD 13 O Host Serial Port Transmit Data RTS Note 2 14 O NC if not used Host Serial Port Request To Send active low CTS Note 3 15 I GND if not used Host Serial Port Clear To Send active low Note 2 Treat As No Connect If RTS is not used Pad required for mechanical stability Note 3 Connect to GND if CTS is not use TABLE 3 Auxiliary Ports ...

Страница 4: ...ype Default Layout Description MVCC 6 I Module internal Voltage Regulator Input VCC_CORE 9 I O Voltage Regulator Input Output VCC 10 I Voltage Regulator Input Baseband VCC_IO 11 I Power Supply I O GND 3 4 17 18 24 29 30 31 32 I GND Must be connected to ground plane NC 1 5 33 34 35 36 37 38 39 40 NC Place Pads for stability See Section 21 0 Physical Dimensions NC 41 42 43 44 45 46 47 48 49 50 51 52...

Страница 5: ...reduce power consumption while waiting for the incoming link Figure 2 shows an example for the connection to a host con troller which can include a simple application to control the LMX9838 The figure also includes the connection to a PCM codec in case the host controller application includes an au dio profile Reset OP4 and OP5 are controlled by the host for full control of the LMX9838 status Plea...

Страница 6: ...00V Human Body ESD rating Note 7 All pins meet 200V Macine Model ESD rating except pins RXD TXD CTS RTS PG4 OP5 PG6 PG7 SCL SDA MDOD1 MWCS SFS STD SRD RATED AT 150v Note 8 All pins meet 1000V Charge Discharge Model ESD rating except pin 69 rated at 250V Recommended Operating Conditions Symbol Parameter Min Typ Max Unit MVCC Module internal Voltage Regulator input 3 0 3 3 3 6 V VCC Digital Voltage ...

Страница 7: ...IOL Logical 0 Output Current VOH 0 4V VCC_IO 3 0V 10 mA Note 14 Guaranteed by design 10 2 RF PERFORMANCE CHARACTERISTICS In the performance characteristics tables the following applies All tests performed are based on Bluetooth Test Specification revision 2 0 All tests are measured at antenna port unless otherwise specified TA 40 C to 85 C VDD_RF 2 8V unless otherwise specified RF system performan...

Страница 8: ...F 27 dBm 2498 MHz FCWI 3000 MHz BER 0 001 27 dBm PinRF 10 dBm 3000 MHz FCWI 12 75 GHz BER 0 001 10 dBm Note 15 Typical operating conditions are at 2 75V operating voltage and 25 C ambient temperature Note 16 The f0 64 dBm Bluetooth modulated signal f1 39dbm sine wave f2 39 dBm Bluetooth modulated signal f0 2f1 f2 and f2 f1 n 1MHz where n is 3 4 or 5 For the typical case n 3 www national com 8 LMX9...

Страница 9: ... for at least 99 9 of all Δf2max Note 19 Modulation index set between 0 28 and 0 35 Note 20 Out of Band spurs only exist at 2nd and 3rd harmonics of the CW frequency for each channel Note 21 Not tested in production Synthesizer Performance Characteristics Symbol Parameter Condition Min Typ Max Unit fVCO VCO Frequency Range 2402 2480 MHz tLOCK Lock Time f0 20 kHz 120 µs Δf0offset Note 22 Initial Ca...

Страница 10: ...to seven slaves Default Link Policy set tings and a specific master mode allow optimized configura tion for the application specific requirements See Sec tion 14 0 Integrated Firmware 11 1 5 Memory The LMX9838 introduces 16 kB of combined system and Patch RAM memory that can be used for data and or code upgrades of the ROM based firmware Due to the flexible startup used for the LMX9838 operating p...

Страница 11: ...gth OKI MSM7717 Advanced audio interface 8 bit log PCM a law only 520 kHz 8 kHz 14 Bits Winbond W681310 Advanced audio interface 8 bit log PCM A law and u law 520 kHz 8 kHz 14 Bits Winbond W681360 Advanced audio interface 13 bit linear 520 kHz 8 kHz 13 Bits PCM slave Note 26 Advanced audio interface 8 16 bits 128 1024 kHz 8 kHz 8 16 Bits Note 26 In PCM slave mode parameters are stored in NVS Bit c...

Страница 12: ...on Issue a Hardware Reset The EEPROM initialization phase will be interrupted and the EEPROM will not be recognized which leaves the device in a lockup situation Once the initialization phase is completed the module sends the SimplyBlue Ready Event refer to the LMX9838 Soft ware User s Guide AN 1699 to declare its fully functional state It is therefore recommended to wait for the SimplyBlue Ready ...

Страница 13: ...wo frequency discrimina tors The I frequency discriminator uses the 90 phase shift ed signal from the Q path while the Q discriminator uses the 90 phase shifted signal from the I path A poly phase band pass filter performs the required phase shifting The output signals of the I and Q discriminator are substracted and fil tered by a low pass filter An equalizer is added to improve the eye pattern f...

Страница 14: ...xers mix the balanced I and Q signals up to 2 4 2 5 GHz The output signals of the I and Q mixers are summed 13 7 32 kHz Oscillator An oscillator is provided see Figure 4 that is tuned to provide optimum performance and low power consumption while op erating with a 32 768 kHz crystal An external crystal clock network is required between the 32k clock input pad 27 and the 32k clock output pad 28 sig...

Страница 15: ... as de scribed in Table 13 Instead all data are directly passed through the firmware to the active bluetooth link and the re mote device Transparent mode can only be supported on a point to point connection To leave Transparent mode the host must send a UART_BREAK signal to the module Force Master Mode In Force Master mode tries to act like an access point for multiple connections For this it will...

Страница 16: ...Link keys for paired devices Security Mode 2 Security mode Page Scan Mode Connectable Connectable Not connectable for other devices Inquiry Scan Mode Discoverable Discoverable Not Discoverable Limited Discoverable for other devices Default Link Policy All modes allowed Configures modes allowed for incoming or outgoing connections Role switch Hold mode Sniff mode Default Link Timeout 20 seconds The...

Страница 17: ...e can disable the transport layer Enabling the transport layer is controlled by the HW Wakeup signalling This can be done from either the Host or the LMX9838 See also LMX9838 Software User s Guide for detailed informa tion on timing and implementation requirements TABLE 12 Power Mode Activity Power Mode UART Activity Radio Activity Reference Clock PM0 OFF OFF none PM1 ON OFF Main Clock PM2 OFF Sca...

Страница 18: ...s ready to receive commands 16 0 Command Interface The LMX9838 offers Bluetooth functionality in either a self contained slave functionality or over a simple command in terface The interface is listening on the UART interface The following sections describe the protocol transported on the UART interface between the LMX9838 and the host in command mode see Figure 8 In Transparent mode no data frami...

Страница 19: ...ect Confirm Create an SDP connection to remote device SDAP Disconnect SDAP Disconnect Confirm Disconnect an active SDAP link Connection Lost Notification for lost SDAP link SDAP Service Browse Service Browse Confirm Get the services of the remote device SDAP Service Search SDAP Service Search Confirm Search a specific service on a remote device SDAP Attribute Request SDAP Attribute Request Confirm...

Страница 20: ...Settings Confirm Get Audio Settings for existing Link Set Volume Set Volume Confirm Configure the volume Get Volume Get Volume Confirm Get current volume setting Mute Mute Confirm Mutes the microphone input TABLE 21 Wake Up Functionality Command Event Description Disable Transport Layer Transport Layer Enabled Disabling the UART Transport Layer and activates the Hardware Wakeup function TABLE 22 S...

Страница 21: ...nfirm Create a new service record within the service database Enable SDP Record Enable SDP Record Confirm Enable or disable SDP records Delete All SDP Records Delete All SDP Records Confirm Ports to Open Ports to Open Confirmed Specify the RFComm Ports to open on startup TABLE 25 Local Hardware Commends Command Event Description Set Default Audio Settings Set Default Audio Settings Confirm Configu...

Страница 22: ... Clock and Baudrate Set Clock and Baudrate Confirm Write Baseband frequency and Baudrate used TABLE 27 GPIO Control Commands Command Event Description Set GPIO WPU Set GPIO WPU Confirm Enable Disable weak pull up resistor on GPIOs Get GPIO Input State Get GPIO Input States Confirm Read the status of the GPIOs Set GPIO Direction Set GPIO Direction Confirm Set the GPIOs direction Input Ouput Set GPI...

Страница 23: ...8 using a 1 8V IO interface 17 1 FILTERED POWER SUPPLY It is important to provide the LMX9838 with adequate ground planes and a filtered power supply It is highly recommended that a 2 2 μF and a 100 nF bypass capacitor be placed as close as possible to the power supply pins VCC MVCC and VCC_IO 17 2 FREQUENCY AND BAUDRATE SELECTION OP3 OP4 OP5 can be strapped to the host logic 0 and 1 levels to set...

Страница 24: ...mended Operating Conditions FIGURE 10 2 5V to 3 0V Example Functional System Schematic 30027910 Notes Capacitor values C1 and C2 may vary depending on design and crystal manufacturer specification MVCC can be connected to 3 0V and above in this configuration Please see Recommended Operating Conditions FIGURE 11 1 8V to 2 5V Example Functional System Schematic www national com 24 LMX9838 ...

Страница 25: ...vary depending on design and crystal manufacturer specification MVCC can be connected to 3 0V and above in this configuration Please see Recommended Operating Conditions FIGURE 12 1 8V Example Functional System Schematic 25 www national com LMX9838 ...

Страница 26: ...18 0 Evaluation Design 30027915 FIGURE 13 www national com 26 LMX9838 ...

Страница 27: ... Aperture 17 mil Stencil Thickness 5 mil Solder Paste Used Defined by customer or manufacturing facility Flux Cleaning Process Defined by customer or manufacturing facility Reflow Profiles See Figure 14 TABLE 29 Classification Reflow Profiles Note 27 Note 28 Profile Feature NOPB Assembly Average Ramp Up Rate TsMAX to Tp 3 C second maximum Preheat Temperature Min TsMIN Temperature Max TsMAX Time ts...

Страница 28: ...ntial installa tion This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that inter ference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be de...

Страница 29: ...21 0 Physical Dimensions inches millimeters unless otherwise noted NS Package Number SB70A 29 www national com LMX9838 ...

Страница 30: ...IGHT LIFE SUPPORT POLICY NATIONAL S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION As used herein Life support devices or systems are devices which a are intended for surgical implant into the body or b support or sustain...

Отзывы: