TABLE 11. Operation Parameters Stored in LMX9838
Parameter
Default Value
Description
BDADDR
Preprogrammed by National
Bluetooth device address
Local Name
Serial port device
PinCode
0000
Bluetooth PinCode
Operation Mode
Automatic ON
Automatic mode ON or OFF
Default Connections
0
Up to seven default devices to connect to
SDP Database
1 SPP entry:
Name: COM1
Authentication and encryption
enabled
Service discovery database, control for supported profiles
UART Speed
9600
Sets the speed of the physical UART interface to the host
UART Settings
1 Stop bit, parity disabled
Parity and stop bits on the hardware UART interface
Ports to Open
0000 0001
Defines the RFComm ports to open
Link Keys
No link keys
Link keys for paired devices
Security Mode
2
Security mode
Page Scan Mode
Connectable
Connectable/Not connectable for other devices
Inquiry Scan Mode
Discoverable
Discoverable/Not Discoverable/Limited Discoverable for other
devices
Default Link Policy
All modes allowed
Configures modes allowed for incoming or outgoing connections
(Role switch, Hold mode, Sniff mode...)
Default Link Timeout
20 seconds
The Default Link Timeout configures the timeout, after which the
link is assumed lost, if no packages have been received from the
remote device
Event Filter
Standard LMX9838 events reported
Defines the level of reporting on the UART
- no events
- standard events
- standard including ACL link events
Default Audio Settings
none
Configures the settings for the external codec and the air format.
• Codecs:
- Winbond W681360
- OKI MSM7717 / Winbond W681310
- PCM Slave
• Air Format:
- CVSD
- µ-Law
- A-Law
www.national.com
16
LMX9838