background image

USER GUIDE AND TERMINAL BLOCK 
SPECIFICATIONS

NI

 

PXIe-4304/4305 and TB-4304

32 Ch, 24-bit, 5 kS/s or 51.2 kS/s Simultaneous Filtered Data 
Acquisition Module

This document explains how to install, configure, and set up the NI PXIe-4304 and 
NI PXIe-4305 (NI PXIe-4304/4305) simultaneous filtered modules with the NI TB-4304 
terminal block.  Driver support for the NI PXIe-4304/4305 was first available in 
NI-DAQmx 15.1.1. For the list of devices supported by a specific release, refer to the 

NI-DAQmx Readme

, available on the version-specific download page or installation media.

Note

The keying of these terminal blocks prevents them from connecting to other 

modules that could be damaged by the voltage present on the terminal block. 
However, you should only use these terminal blocks with their supported modules.

Contents

Electromagnetic Compatibility Guidelines .............................................................................. 2
What You Need to Get Started ................................................................................................. 2
Installation ................................................................................................................................ 3

Install the Software........................................................................................................... 3
Unpack and Install the Module......................................................................................... 3
Connect the Signals .......................................................................................................... 5
Install the Terminal Block ................................................................................................ 8
Confirm NI PXIe-4304/4305 Module Recognition.......................................................... 9
Run Test Panels ................................................................................................................ 10
Take an NI-DAQmx Measurement .................................................................................. 11

NI-DAQmx Channels and Tasks.............................................................................. 11
Configure a Task Using the DAQ Assistant in MAX .............................................. 11

Use Your NI PXIe-4304/4305 Module in an Application................................................ 12

Programming Examples ........................................................................................... 12

Terminal Block Removal.......................................................................................................... 12
Module Removal ...................................................................................................................... 13
Create a Simulated Device ....................................................................................................... 14
More Information ..................................................................................................................... 14

Troubleshooting................................................................................................................ 15

Содержание TB-4304

Страница 1: ...se terminal blocks prevents them from connecting to other modules that could be damaged by the voltage present on the terminal block However you should only use these terminal blocks with their suppor...

Страница 2: ...ed for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in residen...

Страница 3: ...ust be an administrator to install NI software and devices on your computer Ensure that the following software is installed before installing the PXIe 4304 4305 and TB 4304 hardware 1 Your application...

Страница 4: ...modules can be placed only in PXI Express Peripheral slots PXI Express Hybrid Peripheral slots and PXI Express System Timing slots Refer to the chassis documentation for details Figure 1 Symbols for...

Страница 5: ...pinout names and locations in Measurement Automation Explorer MAX at any time by right clicking the device name under Devices and Interfaces and selecting Device Pinouts 1 Loosen the captive top cove...

Страница 6: ...determine the function of the terminal The NI PXIe 4304 4305 User Manual provides more detailed wiring information Make sure no exposed wire extends past the screw terminal Exposed wire increases the...

Страница 7: ...n relief screws 9 Use tie wraps to connect the shielded signal wires to the tie wrap holes for additional strain relief when necessary 10 Reinstall the top cover and tighten the captive top cover scre...

Страница 8: ...of the terminal block 3 Tighten the mounting screw at the top of the TB 4304 to attach it to the NI PXIe 4304 4305 module Note For safety purposes and to prevent damage to equipment when high voltage...

Страница 9: ...configuring channels and tasks and getting started developing an application For detailed NI software version support refer to the NI DAQmx Readme 1 Launch MAX 2 Expand Devices and Interfaces and expa...

Страница 10: ...ection for instructions for creating NI DAQmx simulated devices 3 Right click the module name and select Self Test When the self test completes a verification message appears If an error occurs refer...

Страница 11: ...the DAQ Assistant in MAX Complete the following steps to create a task using the DAQ Assistant in MAX 1 In MAX right click Data Neighborhood and select Create New to open the DAQ Assistant 2 Select N...

Страница 12: ...erminal Block Removal To remove the terminal block refer to Figure 7 while completing the following steps Note The chassis can be powered on or off when removing the terminal block 1 Loosen the termin...

Страница 13: ...he PXI Express system refer to the Maintain Forced Air Cooling Note to Users 1 Make sure that the chassis is powered off before removing the module 2 Loosen the captive screws on the top and bottom of...

Страница 14: ...device in MAX 1 Launch MAX 2 Right click Devices and Interfaces Create New 3 From the dialog select Simulated NI DAQmx Device or Modular Instrument 4 Type 4304 or 4305 in the text box at the top of t...

Страница 15: ...port install or ni com kb If you need to return your National Instruments hardware for repair or device calibration go to ni com info and enter rdsenn to start the Return Merchandise Authorization RMA...

Страница 16: ...turning it to service Environmental Specifications Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor use only Operating Environment Ambient temperature range 0 C...

Страница 17: ...ds the requirements of MIL PRF 28800F Class 3 Safety Measurement Category I1 Caution Do not connect the TB 4304 to signals or use for measurements within Measurement Categories II III or IV Caution Th...

Страница 18: ...1 is any industrial scientific or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection analysis purposes Note For the standards app...

Страница 19: ...n not included in this document Waste Electrical and Electronic Equipment WEEE EU Customers At the end of the product life cycle all products must be sent to a WEEE recycling center For more informati...

Страница 20: ...ivate expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52 227 14 DFAR 252 227 7014 and DFAR 252 227 7015 World Wide Support and Services The Natio...

Отзывы: